• Anesthesiology · Oct 2013

    Accuracy of Plateau Pressure and Stress Index to Identify Injurious Ventilation in Patients with Acute Respiratory Distress Syndrome.

    • Pier Paolo Terragni, Claudia Filippini, Arthur S Slutsky, Alberto Birocco, Tommaso Tenaglia, Salvatore Grasso, Tania Stripoli, Daniela Pasero, Rosario Urbino, Vito Fanelli, Chiara Faggiano, Luciana Mascia, and V Marco Ranieri.
    • * Assistant Professor, † Statistician, § Resident, ** Associate Professor, †† Professor, Dipartimento di Anestesiologia e Rianimazione, Università di Torino, Ospedale S. Giovanni Battista-Molinette, Torino, Italy. ‡ Professor, Keenan Research Center at the Li Ka Shing Knowledge Institute of St. Michael's Hospital; Department of Medicine and Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, Ontario, Canada. ‖ Assistant Professor, # Statistician, Sezione di Anestesiologia e Rianimazione, Dipartimento dell'Emergenza e dei Trapianti d'Organo, Università di Bari, Bari, Italy.
    • Anesthesiology. 2013 Oct 1; 119 (4): 880-9.

    BackgroundGuidelines suggest a plateau pressure (PPLAT) of 30 cm H(2)O or less for patients with acute respiratory distress syndrome, but ventilation may still be injurious despite adhering to this guideline. The shape of the curve plotting airway pressure versus time (STRESS INDEX) may identify injurious ventilation. The authors assessed accuracy of PPLAT and STRESS INDEX to identify morphological indexes of injurious ventilation.MethodsIndexes of lung aeration (computerized tomography) associated with injurious ventilation were used as a "reference standard." Threshold values of PPLAT and STRESS INDEX were determined assessing the receiver-operating characteristics ("training set," N = 30). Accuracy of these values was assessed in a second group of patients ("validation set," N = 20). PPLAT and STRESS INDEX were partitioned between respiratory system (Pplat,Rs and STRESS INDEX,RS) and lung (PPLAT,L and STRESS INDEX,L; esophageal pressure; "physiological set," N = 50).ResultsSensitivity and specificity of PPLAT of greater than 30 cm H(2)O were 0.06 (95% CI, 0.002-0.30) and 1.0 (95% CI, 0.87-1.00). PPLAT of greater than 25 cm H(2)O and a STRESS INDEX of greater than 1.05 best identified morphological markers of injurious ventilation. Sensitivity and specificity of these values were 0.75 (95% CI, 0.35-0.97) and 0.75 (95% CI, 0.43-0.95) for PPLAT greater than 25 cm H(2)O versus 0.88 (95% CI, 0.47-1.00) and 0.50 (95% CI, 0.21-0.79) for STRESS INDEX greater than 1.05. Pplat,Rs did not correlate with PPLAT,L (R(2) = 0.0099); STRESS INDEX,RS and STRESS INDEX,L were correlated (R(2) = 0.762).ConclusionsThe best threshold values for discriminating morphological indexes associated with injurious ventilation were Pplat,Rs greater than 25 cm H(2)O and STRESS INDEX,RS greater than 1.05. Although a substantial discrepancy between Pplat,Rs and PPLAT,L occurs, STRESS INDEX,RS reflects STRESS INDEX,L.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.