• AJNR Am J Neuroradiol · Jun 1998

    Comparative Study

    Activation of the sensorimotor cortex at 1.0 T: comparison of echo-planar and gradient-echo imaging.

    • B F van der Kallen, L J van Erning, M W van Zuijlen, H Merx, and H O Thijssen.
    • Department of Radiology, University Hospital Nijmegen, The Netherlands.
    • AJNR Am J Neuroradiol. 1998 Jun 1; 19 (6): 1099-104.

    PurposeThe increasing demand for the clinical application of functional MR imaging raises the question of whether this technique can be routinely performed on 1.0-T MR scanners. To this end, we assessed the feasibility of functional MR imaging at 1.0 T.MethodsHealthy volunteers were scanned during the performance of a motor task. Functional data were acquired with echo-planar imaging (EPI) and with gradient-echo (GRE) and dual-echo GRE sequences. The signal intensity variations of the EPI and GRE sequences were compared, and the influence of inflow and blood oxygen level-dependent (BOLD) effects on the signal variations was assessed with the dual-echo GRE sequences.ResultsIn 11 of the 12 subjects we found activation in the primary motor cortex with both the GRE and EPI sequences. Active voxels had a significantly higher mean percentage of signal changes with the EPI sequence than with the GRE sequence (EPI: 1% to 6.1%, mean 2.4%; GRE: 1% to 4.5%, mean 1.9%). The EPI sequence was less sensitive to motion artifacts and enabled imaging of a larger brain volume in a shorter time. With a dual-echo sequence we found an increasing contribution of inflow effect with an increasing percentage of signal changes.ConclusionFunctional MR imaging of the sensorimotor cortex can be routinely performed at 1.0 T.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.