- Laurence Bisch, Antoine Da Costa, Virginie Dauphinot, Cécile Romeyer-Bouchard, Lila Khris, Alassane M'baye, and Karl Isaaz.
- 1Division of Cardiology, University Jean Monnet, Saint-Etienne, France.
- Europace. 2010 Aug 1; 12 (8): 1141-8.
AimsThe usefulness of cardiac resynchronization therapy (CRT) in patients with congestive heart failure is offset by its long, user-dependent, and technical procedure. No studies have been published regarding factors related to CRT implantation procedure duration and X-ray exposure. Additionally, only a few studies have investigated the predictive factors of primary left ventricular (LV) lead implant failure. The aim of this prospective study was two-fold: (i) to evaluate the prevalence and predictive factors of prolonged CRT implantation procedure and (ii) to identify the predictive factors of primary LV lead implantation failure.Methods And ResultsBetween November 2008 and September 2009, 128 consecutive patients underwent CRT implantation; of these, 22 patients (17.2%) were excluded because of CRT generator replacement. Population characteristics were a mean age of 69 +/- 10 years, 28.3% female, New York Heart Association class 3.2 +/- 0.3, LV ejection fraction (LVEF; 29 +/- 6%), and QRS width 146 +/- 23 ms. Cardiac resynchronization therapy implantation was attempted in 106 patients, and first LV lead implantation was obtained in 96 of 106 patients (90.5% primary success). Ten primary implantations failed (9.5%), due to unsuccessful LV lead implants. A second procedure was successfully attempted in six patients with a second more experienced operator (5.7%). Among the remaining four patients, one patient required a surgical epicardial LV lead implantation, and the implantation was not reattempted in the other three patients. The overall success rate of CRT system implantation was 96.2% (102 of 106 patients). Procedure parameters were as follows: LV threshold (1.4 +/- 0.9 V); LV wave amplitude (15 +/- 8 mV); LV impedance (874 +/- 215 ohm); median procedure time (skin to skin), 55 min (45-80); and median of procedure fluoroscopy time, 11 min (6.2-29). In 24 patients (22.6%), difficult procedures requiring >or=85 min of implantation duration occurred. By univariate analysis, predictive factors of difficult implantation were LV ejection fraction (25.6 +/- 6 vs. 30.2 +/- 8%; P = 0.02), LV end-diastolic diameter (72.4 +/- 11 vs. 66 +/- 11 mm; P = 0.01), LV end-systolic diameter (LVESD; 62 +/- 12 vs. 56 +/- 12 mm, P = 0.04), and the operator's experience (very experienced operator vs. less experienced operator, P = 0.006). By multivariate analysis, only primary LV lead implantation failure, LVESD, and operator's experience were independently associated with difficult procedures. In this patient subset with primary LV lead implant failure (n = 10), the only independent predictive factor was the LV end-systolic volume (P = 0.03).ConclusionIn this study, the rate of difficult CRT device implantation procedures approached 25%. Both the degree of LV dysfunction and the operator's experience were independent predictors of surgical difficulties. Left ventricular end-systolic volume was the only independent predictor of primary LV lead implant failure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.