Investigative radiology · Sep 2008
Feasibility of gadofosveset-enhanced steady-state magnetic resonance angiography of the peripheral vessels at 3 Tesla with Dixon fat saturation.
- Henrik J Michaely, Ulrike I Attenberger, Olaf Dietrich, Peter Schmitt, Kambiz Nael, Harald Kramer, Maximilian F Reiser, Stefan O Schoenberg, and Michael Walz.
- Institute of Clinical Radiology and Nuclear Medicine, University Hospital Mannheim, University of Heidelberg, Mannheim, Germany. henrik.michaely@rad.ma.uni-heidelberg.de
- Invest Radiol. 2008 Sep 1; 43 (9): 635-41.
IntroductionTo investigate the feasibility and image quality of gadofosveset-enhanced steady-state peripheral MR-angiography using Dixon fat saturation in comparison to spectral fat saturation.Materials And MethodsAfter Institutional Review Board (IRB) approval, 10 healthy volunteers underwent peripheral MR-angiography at 3.0 T during the steady state 50 minutes after gadofosveset injection. A steady-state-adapted volume interpolated breathhold examination sequence with an isotropic spatial resolution of 1 mm was acquired with 2-point Dixon fat saturation (DixFS, acquisition time 52 seconds) and with conventional, spectral fat saturation (SFS, acquisition time 58 seconds). The quality of the images was rated on an ordinal 4-point scale (4, very good) by 2 radiologists in consensus. The signal-to-noise ratios (SNRs) of the vessels, the fat, and the muscles as well as the contrast-to-noise-ratio (CNR) between vessels, fat, and muscle were determined. Paired P tests were performed for statistical analysis with a significance level of P < 0.05.ResultsDiagnostic image quality was achieved in all examinations. The image quality of the DixFS images was rated superior (median 4) over the SFS images (median 3; P = 0.03). The SNR of muscles and vessels was 40% higher with DixFS (P < 0.008), whereas the SNR of fat was decreased by 40.3% from 40.7 with SFS to 22.4 with DixFS (P < 0.0001). The CNR (fat/muscle) of the DixFS images of 84.1/71.7 was significantly higher than the CNR of the SFS images of 47.7/47.4 (P < 0.001).DiscussionTwo-point Dixon fat suppression for MR-angiography during the steady state after the administration of gadofosveset is feasible with superior image quality and more than 50% increase in CNR (fat/muscle) compared with spectral fat saturation without an additional time penalty.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.