J Magn Reson Imaging · Apr 2006
Comparative StudyT1rho relaxation mapping in human osteoarthritis (OA) cartilage: comparison of T1rho with T2.
- Ravinder R Regatte, Sarma V S Akella, J H Lonner, J B Kneeland, and Ravinder Reddy.
- Department of Radiology, Center for Biomedical Imaging, New York University School of Medicine, New York, New York 10003, USA.
- J Magn Reson Imaging. 2006 Apr 1; 23 (4): 547-53.
PurposeTo quantify the spin-lattice relaxation time in the rotating frame (T1rho) in various clinical grades of human osteoarthritis (OA) cartilage specimens obtained from total knee replacement surgery, and to correlate the T1rho with OA disease progression and compare it with the transverse relaxation time (T2).Materials And MethodsHuman cartilage specimens were obtained from consenting patients (N = 8) who underwent total replacement of the knee joint at the Pennsylvania Hospital, Philadelphia, PA, USA. T2- and T1rho-weighted images were obtained on a 4.0 Tesla whole-body GE Signa scanner (GEMS, Milwaukee, WI, USA). A 7-cm diameter transmit/receive quadrature birdcage coil tuned to 170 MHz was employed.ResultsAll of the surgical knee replacement OA cartilage specimens showed elevated relaxation times (T2 and T1rho) compared to healthy cartilage tissue. In various grades of OA specimens, the T1rho relaxation times varied from 62 +/- 5 msec to 100 +/- 8 msec (mean +/- SEM) depending on the degree of cartilage degeneration. However, T2 relaxation times varied only from 32 +/- 2 msec to 45 +/- 4 msec (mean +/- SEM) on the same cartilage specimens. The increase in T2 and T1rho in various clinical grades of OA specimens were approximately 5-50% and 30-120%, respectively, compared to healthy specimens. The degenerative status of the cartilage specimens was also confirmed by histological evaluation.ConclusionPreliminary results from a limited number of knee specimens (N = 8) suggest that T1rho relaxation mapping is a sensitive noninvasive marker for quantitatively predicting and monitoring the status of macromolecules in early OA. Furthermore, T1rho has a higher dynamic range (>100%) for detecting early pathology compared to T2. This higher dynamic range can be exploited to measure even small macromolecular changes with greater accuracy compared to T2. Because of these advantages, T1rho relaxation mapping may be useful for evaluating early OA therapy.2006 Wiley-Liss, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.