• Eur Spine J · Aug 2004

    Comparative Study

    A two-cage reconstruction versus a single mega-cage reconstruction for lumbar interbody fusion: an experimental comparison.

    • Hideki Murakami, William C Horton, Katsuro Tomita, and William C Hutton.
    • Department of Orthopaedic Surgery, Kanazawa University, Kanazawa, Japan.
    • Eur Spine J. 2004 Aug 1; 13 (5): 432440432-40.

    BackgroundInterbody cages are used as an adjunct to anterior lumbar interbody fusion, but exposure and insertion of two cages can be difficult. A biomechanical study was performed to compare the stability and exposed surface for fusion obtained with interbody reconstruction using two traditional cylindrical cages (18-mm diameter) vs. a single expanded mega-cage (24-mm diameter). A single-cage technique could result in safer exposure, shorter operating time, and less cost.Study Designnondestructive testing of L5-S1 motion segments with cages compared the two configurations, and direct measure of the size of the fusion bed was made.Patient Sample16 human cadaveric lumbar motion segments.Outcome Measuressignificant differences in motion segment stiffness and cancellous surface areas were compared using a Wilcoxon rank sum test. Motion segments were biomechanically tested intact, and then tested again after insertion of two interbody cages (n=8) or a single mega-cage (n=8). Nondestructive biomechanical loading was performed consisting of: (1) compression (maximum load 900 N); (2) Flexion, extension, left and right lateral bending (maximum moment 18 Nm); and (3) left and right torsion (maximum moment 10 Nm). From the load-deformation curves obtained, stiffness values were calculated to compare the two-cage and the single mega-cage reconstructions. After testing, the specimens were disarticulated and the surface area of the endplate bed created in the cancellous bone (of both vertebrae) was measured to compare the potential vascular surface for osteogenesis with both constructs.ResultsThe averages of the normalized values of stiffness were significantly greater for the two-cage group as compared to the mega-cage group in flexion only (1.08 vs. 0.74, p<0.05). For extension, torsion and lateral bending there was no significant difference in stiffness. In compression the two-cage group was stiffer, although not significantly (0.92 vs. 0.68, p<0.07). The average cancellous bed surface area was slightly greater for the single-cage reconstruction (1,208 mm(2) vs. 1,155 mm(2)), although this difference was not significant.ConclusionsThe stiffness with a single anterior mega-cage was significantly lower in flexion compared with two standard cages. However, in all other modes of testing the constructs were statistically equivalent, although neither construct was significantly stiffer than the intact specimen. Additionally, the single mega-cage provides an equivalent cancellous bed for fusion as compared to dual cages. While this study is not sufficient to recommend human application, these results and our previous experience with the successful in vivo use of a single cage in rhesus monkeys [4] suggest that the single expanded anterior cage may be an acceptable concept although subsidence risk needs further investigation. The potential advantages of a single mega-cage (safer for the foramen, safer for the vessels, more consistent decortication and possibly cheaper) further suggest that examination should be given to this method as an approach to anterior interbody reconstruction in selected patients.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…