-
- Hing-Chiu Chang, Chun-Jung Juan, Hui-Chu Chiu, Yi-Jui Liu, Cheng-Chieh Cheng, Su-Chin Chiu, Cheng-Yu Chen, Guo-Shu Huang, and Hsiao-Wen Chung.
- Department of Electrical Engineering and Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, No. 1, Sec 4, Roosevelt Road, MD-624, Taipei, Taiwan.
- Radiology. 2013 Jun 1; 267 (3): 918-23.
PurposeTo evaluate the effectiveness of three fat measurement methods for parotid glands in healthy subjects, with or without metallic dental implants.Materials And MethodsThe institutional review board approved this study, with informed consent obtained from 114 volunteers undergoing magnetic resonance (MR) imaging at 1.5 T. Fat-saturated (FS) and non-fat-saturated (NFS) fast spin-echo T1-weighted imaging (T1 method), FS and NFS T2-weighted periodically rotated overlapping parallel lines with enhanced reconstruction fast spin-echo imaging (T2 method), and gradient-echo imaging with fat-water separation using iterative decomposition with echo asymmetry and least squares (IDEAL) method were used to derive parotid fat contents. Two raters examined the homogeneity of fat saturation to determine whether parotid fat quantification was successful, with the success rate in the 114 subjects recorded for each protocol. In subjects whose fat quantification was successful with all three imaging methods, linear regression was used to analyze the correlation between any pair of the three parotid fat content measurement methods.ResultsSuccess rates in parotid fat measurements by using T1, T2, and IDEAL methods were 87.7% (100 of 114), 87.7% (100 of 114), and 100% (114 of 114), respectively. The means of measured parotid fat contents revealed significant differences (P < .001) between any pair of the three measurement methods. The parotid fat contents measured with the three methods were significantly correlated with each other between any pair of combinations.ConclusionThe IDEAL method provided a high success rate for parotid fat measurements, even in subjects with metallic dental implants.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.