    Effect of Inspiratory Time and Lung Compliance on Flow Bias Generated During Manual Hyperinflation: A Bench Study.

    • Bradley G Bennett, Peter Thomas, and George Ntoumenopoulos.
    • Australian Catholic University, North Sydney, New South Wales, Australia.
    • Respir Care. 2015 Oct 1; 60 (10): 144914581449-58.

    BackgroundManual hyperinflation can be used to assist mucus clearance in intubated patients. The technique's effectiveness to move mucus is underpinned by its ability to generate flow bias in the direction of expiration, and this must exceed specific thresholds. It is unclear whether the inspiratory times commonly used by physiotherapists generate sufficient expiratory flow bias based on previously published thresholds and whether factors such as lung compliance affect this.MethodsIn a series of laboratory experiments, we applied manual hyperinflation to a bench model to examine the role of 3 target inspiratory times and 2 lung compliance settings on 3 measures of expiratory flow bias.ResultsLonger inspiratory times and lower lung compliances were associated with improvements in all measures of expiratory flow bias. In normal compliance lungs, achievement of the expiratory flow bias thresholds were (1) never achieved with an inspiratory time of 1 s, (2) rarely achieved with an inspiratory time of 2 s, and (3) commonly achieved with an inspiratory time of 3 s. In lower compliance lungs, achievement of the expiratory flow bias thresholds was (1) rarely achieved with an inspiratory time of 1 s, (2) sometimes achieved with an inspiratory time of 2 s, and (3) nearly always achieved with an inspiratory time of 3 s. Peak inspiratory pressures exceeded 40 cm H2O in normal compliance lungs with inspiratory times of 1 s and in lower compliance lungs with inspiratory times of 1 and 2 s.ConclusionsInspiratory times of at least 3 s with normal compliance lungs and at least 2 s with lower compliance lungs appear necessary to achieve expiratory flow bias thresholds during manual hyperinflation. Inspiratory times shorter than this may lead to excessive peak inspiratory pressures. Verification of these findings in relation to the movement of mucus should be examined in further bench or animal models and/or human clinical trials.Copyright © 2015 by Daedalus Enterprises.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.