PurposeTo establish the normal measurements of diameter and cross-sectional area of the Chinese extraocular muscles (EOMs) and optic nerve-sheath complex (ON) as seen on high-field (3-Tesla; 3T) magnetic resonance imaging (MRI).MethodsCoronal 3T MRI of the orbit (TR, 700 ms; TE, 15 ms; FOV, 160 mm; matrix, 256 x 256; slice thickness, 1 mm; and slice gap, 0) was performed on 80 normal Chinese volunteers. T1-weighted images were analyzed with computer-assisted segmentation. The diameter and the cross-sectional area of EOMs and the ON were measured from the image plane at the posterior aspect of the globe and at 7 mm behind the globe. The maximum diameter of EOM was measured from their respective reconstructed images.ResultsThe normal measurement (mean +/- SD) of diameter at the posterior aspect of the globe: medial rectus (MR), 3.6 +/- 0.4 mm; inferior rectus (IR), 3.7 +/- 0.8 mm; lateral rectus (LR), 2.3 +/- 0.5 mm; superior oblique (SO), 2.4 +/- 0.6 mm; and the ON, 5.4 +/- 0.7 mm. The normal measurement of diameter 7 mm behind the globe: MR, 3.2 +/- 0.6 mm; IR, 3.9 +/- 0.8 mm; LR, 4.0 +/- 0.8 mm; SO, 2.2 +/- 0.7 mm; and ON, 4.2 +/- 0.5 mm. The normal measurement of cross-sectional area at the posterior aspect of the globe: superior muscle group (SMG), 28.2 +/- 6.5 mm(2); MR, 25.5 +/- 3.2 mm(2); IR, 26.9 +/- 7.2 mm(2); LR, 17.3 +/- 3.9 mm(2); SO, 10.5 +/- 3.5 mm(2); and ON, 27.6 +/- 6.1 mm(2). The normal measurement of cross-sectional area 7 mm behind the globe: SMG, 24.1 +/- 6.6 mm(2); MR, 19.1 +/- 4.6 mm(2); IR, 29.5 +/- 6.6 mm(2); LR, 32.3 +/- 6.5 mm(2); SO, 9.7 +/- 3.9 mm(2); and ON, 17.1 +/- 2.9 mm(2). The normal measurement of maximum diameter: SMG, 4.8 +/- 1.1 mm; MR, 5.1 +/- 0.9 mm; IR, 5.4 +/- 1.0 mm; and LR, 4.5 +/- 0.9 mm.ConclusionsThe Chinese 3T MRI EOMs and ON normative data may be useful in determining pathologic enlargement of the EOMs and ON in various orbital conditions. (ClinicalTrials.gov number, NCT00348413.).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.