-
Investigative radiology · Sep 2008
Comparative StudyDiffusion tensor magnetic resonance imaging of the human calf: comparison between 1.5 T and 3.0 T-preliminary results.
- Nadja Saupe, Lawrence M White, Marshall S Sussman, Andrea Kassner, George Tomlinson, and Michael D Noseworthy.
- Joint Department of Medical Imaging, Mount Sinai Hospital and the University Health Network, University of Toronto, Toronto, Ontario, Canada. nadja.saupe@balgrist.ch
- Invest Radiol. 2008 Sep 1; 43 (9): 612-8.
ObjectivesTo compare diffusion tensor-magnetic resonance imaging (DT-MRI) of human calf muscles at 1.5 T and 3.0 T, and to measure a number of quantitative parameters to characterize diffusion anisotropy in organized muscle tissue using similar imaging parameters.Methods And MaterialsAfter Institutional Review Board approval and informed consent, five healthy volunteers were studied. Imaging was performed on both 1.5 T and 3.0 T MR systems using the similar imaging protocol. Diffusion-sensitized single-shot spin-echo echo planar imaging pulse sequences were used to collect 2-dimensional images through the calf. Imaging was performed using b-values of 0, 300, 500, and 700 s/mm. Image analyses and tensor calculations were performed offline using DT imaging studio (Johns Hopkins University, Baltimore, MD). The eigenvalues (lambda1, lambda2, lambda3), trace of the diffusion tensor (TrD), fractional anisotropy, relative anisotropy, and volume ratio were calculated in 3 different calf muscles (medial and lateral gastrocnemius and soleus). Signal-to-noise ratios (SNRs) were compared for both field strengths (1.5 T and 3.0 T), the different muscles and all b-values. A regression analysis was performed to look at within-subject effects (linear mixed effect model).ResultsNo significant differences were found between all quantitative measured DT-MRI parameters, b-values, and muscle groups at 3.0 T and 1.5 T (P = 0.105; P = 0.719). The mean of SNR on the 2 different field strengths (3.0:1.5 T) was 1.64, which was significantly different (P < 0.0001). Significant differences in SNR in all 3 muscles were found between sequences using b = 300 s/mm and 700 s/mm (P < 0.001; P = 0.006) and between sequences using b = 300 s/mm and 500 s/mm (P < 0.001; P = 0.03), and 500 s/mm and 700 s/mm (P = 0.005; P = 0.03), respectively, for medial gastrocnemius and soleus muscle.ConclusionsThis study demonstrates useful parameters to perform DT-MRI at 1.5 T and 3.0 T. DT-MRI at 1.5 T and 3.0 T provide in vivo validation of quantitative structural analysis of human skeleletal muscle.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.