-
J Comput Assist Tomogr · May 2020
Comparative StudyIntravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging.
- Qi Wan, Qiang Lei, Peng Wang, Jianfeng Hu, Tianjing Zhang, Deng Yu, Xinchun Li, and Changhong Liang.
- Department of Radiology, the First Affiliated Hospital of Guangzhou Medical University.
- J Comput Assist Tomogr. 2020 May 1; 44 (3): 334-340.
ObjectiveThe aim of the study was to compare intravoxel incoherent motion diffusion-weighted imaging (DWI) for evaluating lung cancer using single-shot turbo spin-echo (TSE) and single-shot echo-planar imaging (EPI) in a 3T MR system.MethodsBoth single-shot TSE-DWI and single-shot EPI-DWI were scanned twice respectively for 15 patients with lung cancer. Distortion ratio, signal-to-noise ratio, and contrast-to-noise ratio were compared between the 2 techniques. The Bland-Altman analysis was performed to analyze reproducibility between the parameters of TSE-DWI and EPI-DWI. Short-term test-retest repeatability, as well as interobserver agreement, was evaluated using the coefficient of variation (CV) and the intraclass correlation coefficient (ICC).ResultTurbo spin-echo DWI has lower signal-to-noise ratio and similar contrast-to-noise ratio compared with EPI-DWI. Distortion ratio of TSE-DWI was significantly smaller than that of EPI-DWI. The apparent diffusion coefficient (ADC) and true diffusivity (D) of TSE-DWI showed higher values than those of EPI-DWI. The Bland-Altman analysis showed unacceptable limits of agreement between these 2 sequences. Test-retest repeatability was good for ADC and D of EPI-DWI (CV, 14.11%-16.60% and 17.08%-19.53%) and excellent for ADC and D of TSE-DWI (CV, 4.8%-6.19% and 6.05%-8.71%), but relatively poor for perfusion fraction (f) and pseudo-diffusion coefficient (D*) (CV, 25.95%-27.70% and 56.92%-71.84% for EPI, 23.67%-28.67% and 60.85%-70.17% for TSE). For interobserver agreement, both techniques were good to excellent in ADC and D (The lower limit of 95% confidence interval for ICC was almost all greater than 0.75), whereas D* and f had higher interobserver variabilities with D* of TSE-DWI showing poorest reproducibility (ICC, -0.27 to 0.12).ConclusionsLung DWI or IVIM using TSE could provide distortion-free images and improve the test-retest robustness of ADC and D as compared with EPI-DWI; however, it might exert a negative effect on perfusion parameter D*.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.