Lung Cancer: Short-Term Reproducibility of Intravoxel Incoherent Motion Parameters and Apparent Diffusion Coefficient at 3T.
- Jianqin Jiang, Jianbin Yin, Lei Cui, Xiaowen Gu, Rongfang Cai, Shenchu Gong, Yiming Xu, Hang Ma, and Jian Mao.
- Department of Radiology, Second Affiliated Hospital of Nantong University, Nantong, Jiangsu, PR China.
- J Magn Reson Imaging. 2018 Apr 1; 47 (4): 1003-1012.
PurposeTo prospectively evaluate the short-term reproducibility of intravoxel incoherent motion (IVIM) parameters and apparent diffusion coefficient (ADC) in lung cancer patients.Materials And MethodsIn all, 50 patients (50 lesions) underwent free-breathing diffusion-weighted imaging (DWI) (b = 0, 300, 800 s/mm2 ) and IVIM (10 b-values, 0-1000 s/mm2 ) scans twice (0.5-1-hour interval) at 3T. Regions of interests (ROIs) were drawn on ADC maps and IVIM images to derive the mean ADC value and IVIM parameters D, D*, and f. Intra- and interobserver, test-retest reproducibility were assessed with intraclass correlation coefficients (ICCs), within coefficient-of-variations (WCVs), and Bland-Altman analysis. The effects of type, size, and location of lung lesions were compared with WCVs.ResultsD and ADC showed good intraobserver reproducibility and interobserver agreement, while D* and f showed relatively larger variability (WCV 20.89-34.97%). The test-retest reproducibility of D and ADC were good (ICC 0.763-0.837; WCV 11.12-12.55%), while those of D* and f were relatively poor (ICC 0.604-0.842; WCV 36.54-72.62%). D and ADC had decreased reproducibility for lesions <2 cm (WCV 14.20%, 16.34%, respectively) and for lesions in the lower lung zones (WCV 16.52%, 14.78%, respectively). f had decreased reproducibility in central lung cancers (WCV 50.11%) and lesions >2 cm (WCV 42.64%). D* had even worse reproducibility in peripheral lung cancers (WCV 84.11%) and lesions in the lower lung zones (WCV 80.84%).ConclusionIf the change in ADC, D, D*, and f values is less than ∼31%, 34%, 170%, and 130%, respectively, it may be caused by measurement error. The type, size, and location of lung lesions have an effect on measurement errors.Level Of Evidence1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2018;47:1003-1012.© 2017 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.