-
- Simin Xie, Ismail Bilal Masokano, Wenguang Liu, Xueying Long, Guijin Li, Yigang Pei, and Wenzheng Li.
- Department of Radiology, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, China.
- Eur J Radiol. 2021 Feb 1; 135: 109472.
PurposeTo compare the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes and readout-segmented EPI (RS-EPI) in the repeatability of apparent diffusion coefficient (ADC) measurements, signal-to-noise ratio (SNR) and image quality.MethodsIn this institutional review board-approved prospective study, hepatic DWIs (b = 50, 300, 600 s/mm2) were performed in 22 volunteers on 3.0 T MRI using SS-EPI with free-breathing diffusion-weighted imaging (FB-DWI), breath-hold (BH-DWI), respiratory-triggered (RT-DWI) and navigator-triggered (NT-DWI), and readout-segmented EPI (RS-DWI). ADC and surrogate SNR (sSNR) were measured in nine anatomic locations in the right lobe, and image quality was assessed on all FB-DWI, BH-DWI, RT-DWI, NT-DWI, and RS-DWI sequences. The sequence with the optimal clinical utility was decided by systematically comparing the ADC repeatability, sSNR and image quality of the above DWIs.ResultsIn all the five sequences, NT-DWI had the most reliable intra-observer agreement (intraclass correlation coefficient (ICC): 0.900-0.922; all P > 0.05), and a better interobserver agreement (ICC: 0.853-0.960; all p > 0.05) than RS-DWI (ICC:0.881-0.916; some P < 0.05). NT-DWI had the best ADC repeatability in the nine locations (mean ADC absolute differences: 38.47-56.38 × 10-6 mm2/s, limits of agreement (LOA): 17.33-22.52 × 10-6 mm2/s). Also, NT-DWI had the highest sSNR (Reader 1: 50.58 ± 20.11 (Superior), 74.06 ± 28.37 (Central), 80.99 ± 38.11(Inferior)); Reader 2: 48.07 ± 23.92 (Superior), 68.23 ± 32.91 (Central), 76.78 ± 33.07 (Inferior)) in three representative sections except for RS-DWI. Furthermore, NT-DWI had a better image quality than RS-DWI (P < 0.05) and was superior to FB-DWI and BH-DWI in sharpness of the liver (at b = 300 s/mm2) (P < 0.05) CONCLUSION: RS-DWI has the best SNR. However, NT-DWI can provide sufficient SNR, excellent image quality, and the best ADC repeatability on 3.0 T MRI. It is thus the recommended sequence for the clinical application of hepatic DWI.Copyright © 2020 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.