-
Investigative radiology · May 2010
Intraindividual in vivo comparison of gadolinium contrast agents for pharmacokinetic analysis using dynamic contrast enhanced magnetic resonance imaging.
- Jiachao Liang, Steffen Sammet, Xiangyu Yang, Guang Jia, Yukihisa Takayama, and Michael V Knopp.
- Department of Radiology, The Ohio State University, Columbus, OH 43210, USA.
- Invest Radiol. 2010 May 1; 45 (5): 233-44.
PurposeTo compare the intraindividual differences of dynamic signal characteristics for 3 gadolinium chelates (gadopentetate dimeglumine [Gd-DTPA], gadodiamide [Gd-DTPA-BMA], and gadobenate dimeglumine [Gd-BOPTA]) using dynamic contrast enhanced magnetic resonance (MR) imaging (DCE-MRI) with a preclinical beagle model at 7 Tesla.Method And MaterialsSeven beagles were scanned 3 times each with a 7-day interval between the scans on a 7T whole body MRI system (Achieva, Philips) using a T/R head coil. Three different Gd contrast agents including Gd-DTPA, Gd-DTPABMA, and Gd-BOPTA were injected in a randomized order with a power injector (Spectris, MedRad, Indianola, PA) using dose of 0.1 mmol/kg body weight and flow rate of 0.06 mL/s. During image acquisition and data analysis, the identity of the specific contrast agent used for each examination was blinded. A 3D RF-spoiled fast field echo sequence was used for dynamic scans with in-plane spatial resolution 0.47 x 0.47 mm(2), temporal resolution of 9.5 seconds, and a total of 60 time points. Regions of interest were drawn within the carotid arteries and muscle tissue to determine semiquantitative parameters including maximum enhancement ratio, area under the signal enhancement curve over 90 seconds after contrast injection (AUC_90), time to maximum signal enhancement (T(max)), and washout_score. Additionally, quantitative pharmacokinetic parameters were measured in muscle tissues by applying 3 separate 2-compartment models; (1) artery input function (AIF) based Tofts model, (2) Brix model without AIF, and (3) AIF decomposed refined Brix model.ResultsGd-BOPTA produced higher signal to noise ratio on postcontrast T1- weighted images than the other 2 Gd based contrast agents at 7T. Quantitatively, Gd-BOPTA provided a significantly higher maximum enhancement ratio (P < 0.01), AUC_90 (P < 0.01) and washout_score (P < 0.01) in beagle musculature and cranial vasculature compared with both Gd-DTPA and Gd-DTPA-BMA. Among all the quantitative pharmacokinetic parameters, only the exchange rate constants (kep) calculated from these 3 models did not show a significant difference among the various contrast agents.ConclusionsGd chelate containing MR contrast agents can be used at 7T for DCEMRI. Gd-BOPTA demonstrates stronger signal enhancement than standard Gd chelates, in concordance with the results of studies at lower fields. The observed enhancement characteristics for the 3 contrast agents demonstrate that the pharmacokinetic parameter kep is more robust in various models using DCE-MRI than the other pharmacokinetic parameters. This information is important relative to multisite clinical trials and long-term clinical studies that often use several different contrast agents and different models.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.