- K O Lövblad, P M Jakob, Q Chen, A E Baird, G Schlaug, S Warach, and R R Edelman.
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Mass, USA.
- AJNR Am J Neuroradiol. 1998 Feb 1; 19 (2): 201-8; discussion 209.
PurposeOur objective was to determine whether a multisection technique, diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) imaging, can compensate for the drawbacks common to other diffusion-weighted techniques; specifically, the need for echo-planar technology and the presence of susceptibility artifacts in areas close to the skull base.MethodsForty subjects who were referred to the stroke service with signs of acute (less than 24 hour) neurologic dysfunction were included in this prospective study. MR imaging of the brain was performed with diffusion-weighted echo-planar and diffusion-weighted HASTE sequences. The images obtained with both sequences were analyzed for the presence of hyperintensities corresponding to ischemic lesions as well as for the presence of image artifacts and distortions.ResultsDiffusion-weighted HASTE images showed areas of hyperintensity corresponding to the infarcts present on diffusion-weighted echo-planar imaging studies without distortion or susceptibility artifacts in all the patients who had a stroke. Twelve patients had no acute ischemic lesions; of these, five had other findings, six had normal findings, and in one patient, a hyperintensity seen on diffusion-weighted echo-planar images proved to be an artifact on diffusion-weighted HASTE images.ConclusionsDiffusion-weighted HASTE is equal to diffusion-weighted echo-planar imaging in the detection of early ischemia. Because of the absence of significant image distortions and other artifacts, diffusion-weighted HASTE permits fast multiplanar imaging in artifact-prone regions, such as the posterior fossa and the inferior frontal and temporal lobes. Diffusion imaging can be performed on conventional systems with strengths of 1.5 T that do not have echo-planar imaging capabilities.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.