• Cochrane Db Syst Rev · Oct 2017

    Review Meta Analysis

    Volume-targeted versus pressure-limited ventilation in neonates.

    • Claus Klingenberg, Kevin I Wheeler, Naomi McCallion, Colin J Morley, and Peter G Davis.
    • Department of Pediatrics, University Hospital of North Norway, Tromsø, Norway, N-9038.
    • Cochrane Db Syst Rev. 2017 Oct 17; 10 (10): CD003666CD003666.

    BackgroundDamage caused by lung overdistension (volutrauma) has been implicated in the development of bronchopulmonary dysplasia (BPD). Modern neonatal ventilation modes can target a set tidal volume as an alternative to traditional pressure-limited ventilation (PLV) using a fixed inflation pressure. Volume-targeted ventilation (VTV) aims to produce a more stable tidal volume in order to reduce lung damage and stabilise the partial pressure of carbon dioxide (pCO2).ObjectivesTo determine whether VTV compared with PLV leads to reduced rates of death and death or BPD in newborn infants and to determine whether use of VTV affected outcomes including air leak, cranial ultrasound findings and neurodevelopment.Search MethodsWe used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 12), MEDLINE via PubMed (1966 to 13 January 2017), Embase (1980 to 13 January 2017) and CINAHL (1982 to 13 January 2017). We also searched clinical trials databases, conference proceedings and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials. We contacted the principal investigators of studies to obtain supplementary information.Selection CriteriaRandomised and quasi-randomised trials comparing VTV versus PLV in infants of less than 44 weeks' postmenstrual age and reporting clinically relevant outcomes.Data Collection And AnalysisWe assessed risk of bias for each trial using Cochrane methodology. We evaluated quality of evidence for each outcome using GRADE criteria. We tabulated mortality, rates of BPD, short-term clinical outcomes and long-term developmental outcomes.Statisticsfor categorical outcomes, we calculated typical estimates for risk ratios (RR), risk differences (RD) and number needed to treat for an additional beneficial outcome (NNTB). For continuous variables, we calculated typical estimates for mean differences (MD). We used 95% confidence intervals (CI) and assumed a fixed-effect model for meta-analysis.Main ResultsTwenty randomised trials met our inclusion criteria; 16 parallel trials (977 infants) and four cross-over trials (88 infants). No studies were blinded and the quality of evidence for outcomes assessed varied from moderate to low.We found no difference in the primary outcome, death before hospital discharge, between VTV modes versus PLV modes (typical RR 0.75, 95% CI 0.53 to 1.07; low quality evidence). However, there was moderate quality evidence that the use of VTV modes resulted in a reduction in the primary outcome, death or BPD at 36 weeks' gestation (typical RR 0.73, 95% CI 0.59 to 0.89; typical NNTB 8, 95% CI 5 to 20) and the following secondary outcomes: rates of pneumothorax (typical RR 0.52, 95% CI 0.31 to 0.87; typical NNTB 20, 95% CI 11 to 100), mean days of mechanical ventilation (MD -1.35 days, 95% CI -1.83 to -0.86), rates of hypocarbia (typical RR 0.49, 95% CI 0.33 to 0.72; typical NNTB 3, 95% CI 2 to 5), rates of grade 3 or 4 intraventricular haemorrhage (typical RR 0.53, 95% CI 0.37 to 0.77; typical NNTB 11, 95% CI 7 to 25) and the combined outcome of periventricular leukomalacia with or without grade 3 or 4 intraventricular haemorrhage (typical RR 0.47, 95% CI 0.27 to 0.80; typical NNTB 11, 95% CI 7 to 33). VTV modes were not associated with any increased adverse outcomes.Authors' ConclusionsInfants ventilated using VTV modes had reduced rates of death or BPD, pneumothoraces, hypocarbia, severe cranial ultrasound pathologies and duration of ventilation compared with infants ventilated using PLV modes. Further studies are needed to identify whether VTV modes improve neurodevelopmental outcomes and to compare and refine VTV strategies.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.