-
- J Booij, J B Habraken, P Bergmans, G Tissingh, A Winogrodzka, E C Wolters, A G Janssen, J C Stoof, and E A van Royen.
- Department of Nuclear Medicine, Academic Medical Center, University of Amsterdam, The Netherlands.
- J. Nucl. Med. 1998 Nov 1; 39 (11): 1879-84.
UnlabelledSeveral SPECT studies reported decreased striatal 123I-N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-iodoph enyl)nortropane ([123I]FP-CIT) binding in patients with Parkinson's disease. For application in routine clinical studies, information on the reliability and reproducibility of the [123I]FP-CIT SPECT technique is critical. This study reports on the reliability and reproducibility of [I23I]FP-CIT SPECT in healthy control subjects and patients with Parkinson's disease using two different analysis protocols: the conventional region of interest (ROI) protocol and a newly developed, fully automatic, operator-independent volume of interest (VOI) protocol.MethodsWe performed repeated [123I]FP-CIT SPECT scans in 6 healthy control subjects and 10 patients with Parkinson's disease to measure scan-to-scan variations. Scintigraphic data were analyzed 3 hr after injection of the radiotracer.ResultsIn controls, the mean test/retest for the ratio of the striatal-to-nonspecific [123I]FP-CIT uptake were (3.79 +/- 0.67/3.82 +/- 0.74) and (4.16 +/- 0.70/4.08 +/- 0.97) for the ROI and VOI technique, respectively. No significant differences were measured between test/retest studies. The mean test/retest variability for the ROI technique was low (7.25%) with excellent reliability (rho = 0.99). In addition, the mean test/retest variability for the VOI technique was also low (7.47%) with very high reliability (rho = 0.95). In Parkinson's disease patients, we found mean test/retest for the striatal-to-nonspecific [123I]FP-CIT ratio of (1.78 +/- 0.23/1.79 +/- 0.25) and (1.83 +/- 0.31/1.85 +/- 0.35) using the ROI and VOI technique, respectively. Also in patients, these results did not differ significantly between test/retest studies. The mean test/retest variability for the ROI technique was low (7.90%) with excellent reliability (rho = 1.00). In addition, the mean test/retest variability for the VOI technique was also low (7.36%) with high reliability (rho = 0.96).ConclusionReliable and reproducible results were obtained with the ROI, as well as the VOI technique, for the analysis of striatal dopamine transporters with [123I]FP-CIT SPECT in healthy controls and Parkinson's disease patients. The use of an operator-independent method will be a great advantage in routine clinical studies.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.