• J Magn Reson Imaging · Aug 2002

    Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver.

    • Maria I Altbach, Eric K Outwater, Theodore P Trouard, Elizabeth A Krupinski, Rebecca J Theilmann, Alison T Stopeck, Mitsuko Kono, and Arthur F Gmitro.
    • Department of Radiology, University of Arizona, Tucson, Arizona 85724, USA. maltbach@u.arizona.edu
    • J Magn Reson Imaging. 2002 Aug 1; 16 (2): 179-89.

    PurposeTo evaluate a multishot radial fast-spin echo (RAD-FSE) method developed to improve the quality of abdominal T2-weighted imaging as well as the characterization of focal liver lesions.Materials And MethodsThe RAD-FSE sequence used in this work consisted of a preparatory period followed by a short echo train (ETL = 16). A novel radial k-space trajectory was used to minimize streaking artifacts due to T2 variations and motion. Small diffusion gradients (b = 1.2 mm/s(2)) were used to improve flow suppression. The quality of images obtained with RAD-FSE was compared to multishot 2DFT fast spin-echo (2DFT-FSE) and half-Fourier acquisition single-shot turbo-spin-echo (HASTE) images using data from 16 patients. A postprocessing algorithm was used to generate multiple high-resolution images (at different effective TE values) as well as a T2 map from a single RAD-FSE data set. The T2 maps were used to differentiate malignant from benign lesions for a set of 33 lesions ranging from 0.8-194 cm(3).ResultsRAD-FSE produces high-resolution images of the liver in a breath-hold without the motion artifacts of 2DFT-FSE methods, and without the blurriness and loss of small lesion detectability of HASTE. The inclusion of diffusion weighting in RAD-FSE decreases the signal from blood in hepatic vessels, which improves lesion visualization. The T2 values obtained by postprocessing a single RAD-FSE data set can differentiate malignant from benign lesions. The mean T2 values obtained for malignancies, hemangiomas, and cysts are 108 +/- 30 msec, 240 +/- 14 msec, and 572 +/- 334 msec, respectively.ConclusionThese results indicate that RAD-FSE produces abdominal images of higher quality than 2DFT-FSE and HASTE. In addition, lesions can be characterized using T2 maps generated from a single RAD-FSE data set.Copyright 2002 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…