IEEE Trans Biomed Eng · Sep 2011
The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift.
- Aaron J Young, Levi J Hargrove, and Todd A Kuiken.
- Center for Bionic Medicine, Rehabilitation Institute of Chicago, Chicago, IL 60611, USA. ajyoung@u.northwestern.edu
- IEEE Trans Biomed Eng. 2011 Sep 1; 58 (9): 2537-44.
AbstractMyoelectric pattern recognition systems for prosthesis control are often studied in controlled laboratory settings, but obstacles remain to be addressed before they are clinically viable. One important obstacle is the difficulty of maintaining system usability with socket misalignment. Misalignment inevitably occurs during prosthesis donning and doffing, producing a shift in electrode contact locations. We investigated how the size of the electrode detection surface and the placement of electrode poles (electrode orientation) affected system robustness with electrode shift. Electrodes oriented parallel to muscle fibers outperformed electrodes oriented perpendicular to muscle fibers in both shift and no-shift conditions (p < 0.01). Another finding was the significant difference (p < 0.01) in performance for the direction of electrode shift. Shifts perpendicular to the muscle fibers reduced classification accuracy and real-time controllability much more than shifts parallel to the muscle fibers. Increasing the size of the electrode detection surface was found to help reduce classification accuracy sensitivity to electrode shifts in a direction perpendicular to the muscle fibers but did not improve the real-time controllability of the pattern recognition system. One clinically important result was that a combination of longitudinal and transverse electrodes yielded high controllability with and without electrode shift using only four physical electrode pole locations.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.