• J Magn Reson Imaging · Feb 2005

    Comparative Study

    Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography.

    • Xiaoming Bi and Debiao Li.
    • Department of Radiology, Northwestern University, Chicago, Illinois, USA.
    • J Magn Reson Imaging. 2005 Feb 1; 21 (2): 133-9.

    PurposeTo evaluate the efficacy of contrast-enhanced coronary magnetic resonance angiography (MRA) at 3.0 T.Materials And MethodsNine healthy human volunteers were studied on a 3.0-T whole-body MR system. A three-dimensional, breathhold, magnetization-prepared, segmented, gradient-echo sequence was used, with injection of 20 mL gadopentetate dimeglumine for each three-dimensional slab. Imaging parameters were optimized based on computer simulations. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), depicted coronary artery length, lumen diameter, and imaging sharpness with contrast agent were evaluated. SNR and CNR were compared to the results from a previous 1.5-T study.ResultsA 53% increment in SNR and a 305% enhancement in CNR were measured with contrast. Vessel length and sharpness depicted were higher and the lumen diameter was lower (all P values < 0.05) in postcontrast images. Compared to previous results from 1.5-T, the SNR, CNR, and vessel sharpness were enhanced at 3.0 T with higher spatial resolution.ConclusionContrast-enhanced, three-dimensional, coronary MRA at 3.0 T is a promising technique for diagnosing coronary artery diseases. Patient studies are necessary to evaluate its clinical utility.(c) 2005 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…