• J Magn Reson Imaging · Jan 2019

    A system using patient-specific 3D-printed molds to spatially align in vivo MRI with ex vivo MRI and whole-mount histopathology for prostate cancer research.

    • Holden H Wu, Alan Priester, Pooria Khoshnoodi, Zhaohuan Zhang, Sepideh Shakeri, Sohrab Afshari Mirak, Nazanin H Asvadi, Preeti Ahuja, Kyunghyun Sung, Shyam Natarajan, Anthony Sisk, Robert Reiter, Steven Raman, and Dieter Enzmann.
    • Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA.
    • J Magn Reson Imaging. 2019 Jan 1; 49 (1): 270-279.

    BackgroundPatient-specific 3D-printed molds and ex vivo MRI of the resected prostate have been two important strategies to align MRI with whole-mount histopathology (WMHP) for prostate cancer (PCa) research, but the combination of these two strategies has not been systematically evaluated.PurposeTo develop and evaluate a system that combines patient-specific 3D-printed molds with ex vivo MRI (ExV) to spatially align in vivo MRI (InV), ExV, and WMHP in PCa patients.Study TypeProspective cohort study.PopulationSeventeen PCa patients who underwent 3T MRI and robotic-assisted laparoscopic radical prostatectomy (RALP).Field Strength/SequencesT2 -weighted turbo spin-echo sequences at 3T.AssessmentImmediately after RALP, the fresh whole prostate specimens were imaged in patient-specific 3D-printed molds by 3T MRI and then sectioned to create WMHP slides. The time required for ExV was measured to assess impact on workflow. InV, ExV, and WMHP images were registered. Spatial alignment was evaluated using: slide offset (mm) between ExV slice locations and WMHP slides; overlap of the 3D prostate contour on InV versus ExV using Dice's coefficient (0 to 1); and 2D target registration error (TRE, mm) between corresponding landmarks on InV, ExV, and WMHP. Data are reported as mean ± standard deviation (SD).Statistical TestingDifferences in 2D TRE before versus after registration were compared using the Wilcoxon signed-rank test (P < 0.05 considered significant).ResultsExV (duration 115 ± 15 min) was successfully incorporated into the workflow for all cases. Absolute slide offset was 1.58 ± 1.57 mm. Dice's coefficient was 0.865 ± 0.035. 2D TRE was significantly reduced after registration (P < 0.01) with mean (±SD of per patient means) of 1.9 ± 0.6 mm for InV versus ExV, 1.4 ± 0.5 mm for WMHP versus ExV, and 2.0 ± 0.5 mm for WMHP versus InV.Data ConclusionThe proposed system combines patient-specific 3D-printed molds with ExV to achieve spatial alignment between InV, ExV, and WMHP with mean 2D TRE of 1-2 mm.Level Of Evidence2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:270-279.© 2018 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.