• Thrombosis research · Jan 2004

    Comparative Study Clinical Trial

    Quality assurance program for whole blood prothrombin time-international normalized ratio point-of-care monitors used for patient self-testing to control oral anticoagulation.

    • Armando Tripodi, Caterina Bressi, Monica Carpenedo, Veena Chantarangkul, Marigrazia Clerici, and Pier Mannuccio Mannucci.
    • Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Department of Internal Medicine, University and IRCCS Maggiore Hospital, Via Pace 9, 20122 Milan, Italy. armando.tripodi@unimi.it
    • Thromb. Res. 2004 Jan 1; 113 (1): 35-40.

    AbstractWhole blood coagulation monitors are increasingly used for patient self-testing to control oral anticoagulation, but there are no comprehensive quality assurance (QA) programs to check their performance. We report on the experience with one of such programs applied in a field study where patients on prothrombin time (PT)-international normalized ratio (INR) self-testing were asked to bring their monitors to the anticoagulation clinic for checking. PT-INR testing was performed three times over 3 months with 14 patient's monitors and test strips on three recalcified QA plasmas by an experienced laboratory operator. Each patient was also asked to perform PT-INR self-testing (his/her own capillary blood) which was then compared to the laboratory PT-INR (plasma). Overall, the comparison between the observed and the consensus PT-INR on QA plasmas was acceptable with the majority of measurements lying within +/-15% or 20% of the consensus values. The comparison between the PT-INR self-testing and the laboratory method was also acceptable: overall, there was no statistical significant difference between the mean PT-INR values and the majority of paired measurements were less than 15% or 20% apart. In conclusion, our results show that the proposed QA scheme is feasible and may be implemented on a larger scale. Monitors should be recalled periodically to the clinic where they have been prescribed to the patient. During each visit, the clinic may check the monitors and patient self-testing performance as described. Such comprehensive QA system would make monitoring of oral anticoagulant treatment by self-testing safer and more effective.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…