• J Magn Reson Imaging · Apr 2016

    Noise robust spatially regularized myelin water fraction mapping with the intrinsic B1-error correction based on the linearized version of the extended phase graph model.

    • Dushyant Kumar, Susanne Siemonsen, Christoph Heesen, Jens Fiehler, and Jan Sedlacik.
    • Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
    • J Magn Reson Imaging. 2016 Apr 1; 43 (4): 800-17.

    PurposeTo improve the quantification accuracy of transverse relaxometry by accounting for B1 -error, after minimizing slice profile imperfections.Materials And MethodsThe slice profile of refocusing pulses was optimized by setting refocusing slice thicknesses three times that of the excitation pulse. The first step of data processing combined the L-curve approach with the linearized version of the extended phase graph model to jointly estimate the temporal regularization constant map and the flip angle error (FAE)-map. The second step improved the noise robustness of the reconstruction by imposing a spatial smoothness constraint on T2 -distributions. The proposed method (spatial-regularization-with-FAE-correction) was evaluated against methods without FAE-correction (conventional-regularization-without-FAE-correction, spatial-regularization-without-FAE-correction) and conventional-regularization-with-FAE-correction using relevant statistics (simulated data: mean square myelin reconstruction error [MSMRE] and averaged-symmetric-Kullbeck-Leibler score [SKL] between returned distributions and ground truths; experimental data: median of mean square error [MMSE] of fitting across entire data-set and coefficient of variation [COV] in white-matter [WM] regions of interest [ROIs]).ResultsIn simulation, our method resulted in reduced MSMRE (at signal-to-noise ratio [SNR] = 200: MSMRESpatial-regularization-without-FAEC  = 0.057; MSMRESpatial-regularization-with-FAEC  = 0.0107) and reduced SKL scores (at SNR = 200: SKLSpatial-regularization-without-FAEC  = 0.061; SKLSpatial-regularization-with-FAEC  = 0.0143). In human volunteers, our method yielded a reduced MSE of fitting (MMSESpatial-regularization-without-FAEC  = (2.26 ± 0.60) × 10(-3) ; MMSESpatial-regularization-with-FAEC  = (1.57 ± 0.44) × 10(-4) )and also resulted in reduced COV (COVSpatial-regularization-without-FAEC  = 0.08-0.19; COVSpatial-regularization-with-FAEC  = 0.09-0.12). In a water-phantom, a good correlation between the absolute value of measured B1 -map and FAE-map was found (regression analysis: slope = 1.04; R(2)  = 0.66).ConclusionThe proposed method resulted in more accurate and noise robust myelin water fraction maps with improved depiction of subcortical WM structures.© 2015 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…