• Investigative radiology · Nov 2008

    Clinical Trial

    Multidetector computed tomography in reperfused acute myocardial infarction. Assessment of infarct size and no-reflow in comparison with cardiac magnetic resonance imaging.

    • Alexis Jacquier, Loïc Boussel, Nicolas Amabile, Jean Michel Bartoli, Philipe Douek, Guy Moulin, Franck Paganelli, Maythem Saeed, Didier Revel, and Pierre Croisille.
    • Department of Radiology, University of Marseille Méditerranée CHU la Timone, Marseille cedex 05, France. alexis.jacquier@ap-hm.fr
    • Invest Radiol. 2008 Nov 1; 43 (11): 773-81.

    Objectives(1) To determine the accuracy of delayed enhancement multidetector computed tomography (MDCT) in measuring the extent of acute myocardial infarct and no-reflow areas using cardiac magnetic resonance imaging (MRI) as standard of reference and (2) to define the optimum timing between injection and MDCT image acquisition to characterize infarcted myocardium and no-reflow areas after reperfusion therapy.Materials And MethodsNineteen patients were prospectively included after acute myocardial infarction and revascularization. Each patient had an MDCT acquisition before and 5 and 10 minutes after injection of 1.5 mL/kg iodinated contrast medium, and a contrast-enhanced MRI at 5 and 10 minutes after injection of 0.2 mmol/kg gadolinium chelate. We assessed image quality and infarct extent using MDCT and MRI, and we measured parameters related to iodinated contrast media kinetics (DeltaHU and DeltaHU ratio).ResultsThe areas of hyperenhanced myocardium located on the MDCT corresponded to the occluded vessel located on the coronary angiogram (kappa = 0.9). There were strong correlations between the extent of hyperenhanced infarcted myocardium on MDCT and MRI at 5 minutes (20.4% +/- 2.7% of left ventricle (LV) and 20.9% +/- 2.4%, respectively, R = 0.85; P < 0.0001) and 10 minutes after injection (21.0% +/- 2.9% of LV and 19.4% +/- 2.5%, respectively, R = 0.80; P < 0.0001). However, the correlation between the area of hypoenhanced myocardium measured using MDCT and CMR 5 minutes after injection (R = 0.86; P < 0.0001) was better than the measurement obtained 10 minutes after injection (R = 0.64; P = 0.002). On contrast-enhanced MDCT, 5 minutes after injection, the signal-to-noise ratio was significantly higher than at 10 minutes after injection in LV blood (28 +/- 1 to 21 +/- 1, respectively; P = 0.0007), normal myocardium (18 +/- 1 to 15 +/- 1; P = 0.0009), and hyperenhanced infarcted myocardium (24 +/- 1 to 20 +/- 1; P = 0.004). MDCT image quality was significantly better at 5 minutes (3.2 +/- 0.1) than at 10 minutes (2.8 +/- 0.2, P = 0.01, kappa = 0.4). The DeltaHU ratio increased slightly but significantly between 5 minutes (0.83 +/- 0.01) and 10 minutes (0.93 +/- 0.01; P = 0.01), suggesting a slow wash-in and wash-out of contrast medium in infarcted myocardium.ConclusionIn ST segment elevation myocardial infarction patients contrast-enhanced MDCT is an accurate method for characterizing and sizing myocardial infarct and no-reflow. Contrast-enhanced MDCT performed 5 minutes after injection yields a higher signal-to-noise ratio and image quality than the 10 minutes time point with no difference in the extent of infarct measurement.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.