-
J. Cardiothorac. Vasc. Anesth. · Apr 2004
Comparative Study Clinical TrialComparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.
- Berthold Bein, Frank Worthmann, Peter H Tonner, Andrea Paris, Markus Steinfath, Jürgen Hedderich, and Jens Scholz.
- Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein Campus, Kiel, Germany. bein@anaesthesie.uni-kiel.de
- J. Cardiothorac. Vasc. Anesth. 2004 Apr 1; 18 (2): 185-9.
ObjectiveContinuous measurement of cardiac output (CCO) is of great importance in the critically ill. However, pulmonary artery thermodilution has been questioned for possible complications associated with right heart catheterization. Furthermore, measurements are delayed in the continuous mode during rapid hemodynamic changes. A new pulmonary artery catheter CCO device (Aortech, Bellshill, Scotland) enabling real-time update of cardiac output was compared with 2 different, less-invasive methods of CCO determination, esophageal Doppler and pulse contour analysis.DesignProspective, observational study.SettingUniversity hospital, single institution.ParticipantsPatients scheduled for elective coronary artery bypass grafting (CABG).InterventionsNone.Measurements And Main ResultsCCO measurements were analyzed using a Bland-Altman plot. Bias between CCO and pulse contour cardiac output (PCCO), and Doppler-derived cardiac output (UCCO) was (mean +/- 1 SD) -0.71 +/- 1 L/min versus -0.15 +/- 1.09 L/min, and between UCCO and PCCO -0.58 +/- 1.06 L/min. Bias was not significantly different among methods, nor were comparative values before and after cardiopulmonary bypass (p > 0.05).ConclusionsAgreement between the CCO method and both less-invasive measurements was clinically acceptable. There were no adverse events associated with the use of either device.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.