    Characterizing and eliminating errors in enhancement and subtraction artifacts in dynamic contrast-enhanced breast MRI: Chemical shift artifact of the third kind.

    • Jamal J Derakhshan, Elizabeth S McDonald, Evan S Siegelman, Mitchell D Schnall, and Felix W Wehrli.
    • Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
    • Magn Reson Med. 2018 Apr 1; 79 (4): 2277-2289.

    PurposeTo characterize errors in enhancement in breast dynamic contrast-enhanced (DCE) MRI studies as a function of echo time and determine the source of dark band artifacts in clinical subtraction images.MethodsComputer simulations, oil and water substitute (methylene chloride), as well as an American College of Radiology quality control phantom were tested. Routine clinical DCE breast MRI study was bracketed with (accelerated) in-phase DCE acquisitions in five patients.ResultsSimulation results demonstrated up to -160% suppression of the expected enhancement caused by differential enhancement of fat and water. Two-dimensional gradient-recalled echo and fat-suppressed 3D GRE phantom imaging confirmed the simulation results and showed that fat suppression does not eliminate the artifact. In vivo in-phase DCE images showed increased enhancement consistent with predictions and also confirmed increased spatial blurring on in-phase 3D gradient-recalled echo images. Combined multi-dimensional partial Fourier and parallel imaging provided a time-equivalent in-phase DCE MRI acquisition.ConclusionErrors in expected enhancement occur in DCE breast MRI subtraction images because of differential enhancement of fat and water and incomplete fat signal suppression. These errors can lead to artificial suppression of enhancement as well as dark band artifacts on subtraction images. These artifacts can be eliminated with a time-equivalent in-phase fat-suppressed 3D gradient-recalled echo sequence. Understanding chemical shift artifact of the third kind, a unique artifact of artificial enhancement suppression in the presence of intravoxel fat and water signal, will aid DCE breast MRI image interpretation. In-phase acquisitions (combined with simultaneous minimum echo time or opposed-phase echoes) may facilitate qualitative, quantitative and longitudinal analysis of contrast enhancement. Magn Reson Med 79:2277-2289, 2018. © 2017 International Society for Magnetic Resonance in Medicine.© 2017 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.