J. Cardiothorac. Vasc. Anesth. · Nov 2021
Comparative StudyEarly and Midterm Clinical Outcomes of Transcatheter Valve-in-Valve Implantation Versus Redo Surgical Aortic Valve Replacement for Aortic Bioprosthetic Valve Degeneration: Two Faces of the Same Medal.
- Aleksander Dokollari, Matteo Cameli, Giulia Elena Mandoli, Didar-Karan S Kalra, Robert Poston, Lindita Coku, Marjela Pernoci, Mirian Miri, Massimo Bonacchi, and Sandro Gelsomino.
- Cardiac Surgery Department, Saint Michael's Hospital, Toronto, Canada; Cardiac Surgery, CARIM, Maastricht University Medical Center, Maastricht, Netherlands. Electronic address: aleksanderdokollari2@gmail.com.
- J. Cardiothorac. Vasc. Anesth. 2021 Nov 1; 35 (11): 3223-3231.
ObjectiveTo compare early and midterm outcomes of transcatheter valve-in-valve implantation (ViV-TAVI) and redo surgical aortic valve replacement (re-SAVR) for aortic bioprosthetic valve degeneration.DesignPatients who underwent ViV-TAVI and re-SAVR for aortic bioprosthetic valve degeneration between January 2010 and October 2018 were retrospectively analyzed. Mean follow-up was 3.0 years.SettingIn-hospital, early, and mid-term outcomes.ParticipantsEighty-eight patients were included in the analysis.InterventionsThirty-one patients (37.3%) had ViV-TAVI, and 57 patients (62.7%) had re-SAVR.Measurements And Main ResultsIn the ViV-TAVI group, patients were older (79.1 ± 7.4 v 67.2 ± 14.1, p < 0.01). The total operative time, intubation time, intensive care unit length of stay, total hospital length of stay, inotropes infusion, intubation >24 hours, total amount of chest tube losses, red blood cell transfusions, plasma transfusions, and reoperation for bleeding were significantly higher in the re-SAVR cohort (p < 0.01). There was no difference regarding in-hospital permanent pacemaker implantation (ViV-TAVI = 3.2% v re-SAVR = 8.8%, p = 0.27), patient-prosthesis mismatch (ViV-TAVI = 12 patients [mean 0.53 ± 0.07] and re-SAVR = ten patients [mean 0.56 ± 0.08], p = 0.4), stroke (ViV-TAVI = 3.2% v re-SAVR = 7%, p = 0.43), acute kidney injury (ViV-TAVI = 9.7% v re-SAVR = 15.8%, p = 0.1), and all-cause infections (ViV-TAVI = 0% v re-SAVR = 8.8%, p = 0.02), between the two groups. In-hospital mortality was 0% and 7% for ViV-TAVI and re-SAVR, respectively (p = 0.08). At three-years' follow-up, the incidence of pacemaker implantation was higher in the re-SAVR group (ViV-TAVI = 0 v re-SAVR = 13.4%, p < 0.01). There were no differences in reintervention (ViV-TAVI = 3.8% v re-SAVR = 0%, p = 0.32) and survival (ViV-TAVI = 83.9% v re-SAVR = 93%, p = 0.10) between the two cohorts.ConclusionsViV-TAVI is a safe, feasible, and reliable procedure.Copyright © 2021 The Authors. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.