-
Comparative Study
Frequency-selective fat suppression MR imaging. Localized asymmetric failure of fat suppression mimicking orbital disease.
- A R Borges, R B Lufkin, A Y Huang, K Farahani, and A C Arnold.
- Department of Radiology, Instituto Portugues de Oncologia de Francisco Gentil, Lisbon, Portugal.
- J Neuroophthalmol. 1997 Mar 1; 17 (1): 12-7.
AbstractOur objectives were to further characterize an artifact related to the localized failure of the frequency-selective (FATSAT) fat suppression magnetic resonance (MR) imaging technique. We constructed two phantoms simulating human orbital anatomy and imaged them on a 1.5-T MR scanner using (FATSAT) and short T1 inversion recovery (STIR) techniques of fat suppression. The first phantom resembled orbit structural configurations; it was imaged in coronal and axial planes and in varying orientations with respect to the main magnetic field (Z axis) to study the features of the artifact and to reproduce the asymmetry seen in clinical cases. We designed the second phantom to enable quantification of the change in artifact size with change in orientation. We imaged the orbits of a normal human volunteer in similar planes and orientations, and compared the results to clinical cases demonstrating the artifact and true orbital disease. The artifact identified with localized failure of FATSAT fat suppression manifested as regions of hyperintensity maximal at fat-air interfaces, with gradual fading of the increased signal with distance from the interfaces. The artifact was most prominent when the interfaces were perpendicular to the axis of the main magnetic field (Z axis). The regions of increased brightness obscured normal orbital structures but were not associated with alterations in the geometry of these structures. Changes in orientation of the interfaces with respect to the Z axis, both in the phantoms and normal volunteer, reproduced the asymmetry of fat suppression failure seen in clinical cases. The relationship of size of the artifact to change in orientation was non-linear. The artifact was not seen on STIR images. We concluded that failure of FATSAT fat suppression may mimic orbital disease, particularly if asymmetric. As predicted by the Maxwell electromagnetism equation, slight variations in orientation of the fat-air interface to the Z axis may produce large asymmetries in fat suppression failure in the orbit. Confirmation may require either comparison with additional pulse sequences [T1-weighted spin echo (T1W SE) or STIR] or repositioning the patient's head to check for persistence of the finding with varying orientations.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.