Catheter Cardiovasc Interv · Sep 2014
Multicenter StudyValve-in-valve implantation of a novel and small self-expandable transcatheter heart valve in degenerated small surgical bioprostheses: the Hamburg experience.
- Patrick Diemert, Moritz Seiffert, Christian Frerker, Thomas Thielsen, Felix Kreidel, Ralf Bader, Johannes Schirmer, Lenard Conradi, Dietmar Koschyk, Renate Schnabel, Hermann Reichenspurner, Stefan Blankenberg, Karl-Heinz Kuck, Hendrik Treede, and Ulrich Schaefer.
- Department of General and Interventional Cardiology, University Heart Center Hamburg, Hamburg, Germany.
- Catheter Cardiovasc Interv. 2014 Sep 1; 84 (3): 486-93.
BackgroundTranscatheter valve-in-valve (VIV) implantation has emerged as a novel treatment option in patients with degenerated aortic bioprostheses and high surgical risk. However, VIV implantation in small aortic bioprostheses using first generation TAVI devices has frequently resulted in high postprocedural gradients and small effective orifice areas. Recently, an updated version of the self-expandable Medtronic CoreValve prosthesis, which is particularly suitable for small aortic annuli, has become available. We report on the feasibility and early results of VIV implantation using this novel device in a series of patients with degenerated small aortic bioprostheses.Methods And Results16 patients from two Hamburg hospitals (age range 72-92 years) underwent implantation of a 23-mm CoreValve Evolut (Medtronic, Minneapolis, MN, USA) transcatheter heart valve into failing aortic bioprostheses with internal diameters below 21 mm. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team mean (logistic EuroSCORE range 9.0-88%). Implantation was successful without relevant remaining aortic regurgitation or signs of stenosis and a marked reduction in postprocedural gradientswas observed in 14 out of 16 patients. The mean gradient was reduced from from 34 mm Hg (SEM 10 mm Hg) to 14 mm Hg (SEM 6 mm Hg). No major device- or procedure-related adverse events occurred during 30-day follow up and clinical improvement was observed.ConclusionsFailing aortic bioprostheses with small internal diameters continue to be a challenging pathology for TAVI due to the risk of high residual gradients and small aortic orifice areas. This report provides first evidence that the 23-mm CoreValve Evolut, a novel self-expanding prosthesis, provides an improved treatment option in these specific patients due to its low profile which resulted in promising early results. © 2013 Wiley Periodicals, Inc.© 2013 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.