J Magn Reson Imaging · Sep 2009
Effect of shot number on the calculated apparent diffusion coefficient in phantoms and in human liver in diffusion-weighted echo-planar imaging.
- Masoud Shiehmorteza, Claude B Sirlin, Tanya Wolfson, Anthony Gamst, Andre E Soumekh, Shay P Heaton, Chad A Kohl, Nicholas Pinto, and Mark Bydder.
- Department of Radiology, University of California, San Diego, California, USA.
- J Magn Reson Imaging. 2009 Sep 1; 30 (3): 547-53.
PurposeTo show the signal intensity varies with shot number in diffusion-weighted (DW) echo-planar imaging (EPI) and affects apparent diffusion coefficient (ADC) calculation.Materials And MethodsThis prospective study was performed on 35 adult patients and 20 volunteers. Measurements were made on a 3T scanner using a breathhold DW spin-echo EPI (SE EPI) sequence. Three protocols were used: A) eight consecutive shots at a fixed b-value of 0 seconds/mm(2) with TR = 1000 and 3000 msec; B) seven consecutive shots at b-values = 0, 1000, 750, 500, 250, 100, 0 seconds/mm(2) (in that order) with TR = 3500 msec; and C) seven consecutive shots (as in B) with TR = 1000, 1750, and 7000 msec.ResultsFor protocol A, signal intensity decreased significantly from the first to second shot (P<0.0001) and thereafter remained constant. For protocol B, the ADC depended on which b = 0 seconds/mm(2) image was used. Using the first b = 0 seconds/mm(2), the mean ADC was 15% higher than using the second b = 0 seconds/mm(2) (P<0.0001). For protocol C, the difference between ADC using the first b = 0 seconds/mm(2) and the second b = 0 seconds/mm(2) decreased as the TR increased.ConclusionThe signal intensity can vary with shot number in SE EPI. For TR > or = 3000 msec, steady-state is attained after one shot. Using data acquired prior to steady-state confounds the calculation of ADC values.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.