J Magn Reson Imaging · Mar 2007
Correction of proton resonance frequency shift temperature maps for magnetic field disturbances using fat signal.
- Andriy V Shmatukha, Paul R Harvey, and Chris J G Bakker.
- Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands. Andriy.Shmatukha@ge.com
- J Magn Reson Imaging. 2007 Mar 1; 25 (3): 579-87.
PurposeTo improve the immunity of the proton resonance frequency shift (PRFS) method of MRI temperature mapping against magnetic field disturbances. Since PRFS is a phase-sensitive method, it misinterprets magnetic field disturbances as artifact temperature changes. If not corrected, the resulting temperature artifacts can completely obscure the true temperature estimation, especially if the temperature elevations are small.Materials And MethodsSince the fat protons experience the same magnetic field disturbances as the water protons, but no temperature-related frequency shift, the fat signal has been used for correcting PRFS temperature maps for the disturbances. A simple correction method is proposed that has either better compensation capability than the phase correction methods previously reported or higher spatial and temporal resolution than the spectroscopic correction methods previously reported. The evaluated method is based on the utilization of several gradient and spin echoes acquired within one repetition interval with water- and fat-selective scans.ResultsIn a series of phantom experiments, the improved method is shown to enable the reconstruction of accurate temperature maps in spite of interscan motion, suboptimal fat-water separation, and a wide range of magnetic field disturbances.ConclusionOur approach can be used for the guidance of thermal therapies involving tissues containing fat or surrounded by fat.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.