• J Vasc Interv Radiol · Jun 2007

    Comparative Study

    Ultrahigh-pressure versus high-pressure angioplasty for treatment of venous anastomotic stenosis in hemodialysis grafts: is there a difference in patency?

    • Dheeraj K Rajan, Tal Platzker, Charmaine E Lok, J Robert Beecroft, Kong T Tan, Kenneth W Sniderman, and Martin E Simons.
    • Division of Vascular and Interventional Radiology, Department of Medical Imaging, Toronto General Hospital, University Health Network-University of Toronto, 585 University Avenue, NCSB 1C-553, Toronto, Ontario M5G 2N2, Canada. dheeraj.rajan@uhn.on.ca
    • J Vasc Interv Radiol. 2007 Jun 1; 18 (6): 709-14.

    PurposeUltrahigh-pressure (UHP) balloon catheters were compared with high-pressure (HP) balloon catheters to determine if there was a difference in patency after percutaneous transluminal angioplasty (PTA) of venous anastomotic stenoses.Materials And MethodsA retrospective study was conducted from January 2001 to September 2005 that included 22 patients with synthetic hemodialysis grafts who underwent 110 PTA procedures for venous anastomotic stenoses. Data collected included graft configuration and location, percent stenosis, balloon type used, residual stenosis, and total access blood flow before and after intervention. Patency from time of initial PTA to the next intervention was estimated with the Kaplan-Meier technique, with initial failures included in the analysis.ResultsA total of 55 PTAs were performed in each group. Technical success rate was 96% (n = 106) and clinical success rate was 100%. Median survival times were 4.6 months for the UHP cohort and 5.4 months for the HP group. When each event was considered independent, the difference was significant (P = .014). However, when each PTA event was considered dependent on earlier PTA events, no significant difference in patency was observed (P = .64). The mean increases in access blood flow rate by ultrasound dilution (available for 71 events) after PTA were 264 mL/min with UHP and 524 mL/min with HP (P = .14, Student t test). One minor complication (0.9%) of focal extravasation after PTA occurred and resolved with prolonged balloon inflation.ConclusionRoutine use of UHP for PTA of venous anastomotic stenoses in synthetic hemodialysis grafts was not associated with any significant change in patency compared with routine HP balloon angioplasty.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.