• Magn Reson Med · Jun 2017

    Comparative Study

    SNR efficiency of combined bipolar gradient echoes: Comparison of three-dimensional FLASH, MPRAGE, and multiparameter mapping with VFA-FLASH and MP2RAGE.

    • Jean-David Jutras, Keith Wachowicz, Guillaume Gilbert, and Nicola De Zanche.
    • Department of Oncology, University of Alberta, Edmonton, Alberta, Canada.
    • Magn Reson Med. 2017 Jun 1; 77 (6): 2186-2202.

    PurposeHigh-bandwidth bipolar multiecho gradient echo sequences are increasingly popular in structural brain imaging because of reduced water-fat shifts, lower susceptibility effects, and improved signal-to-noise ratio (SNR) efficiency. In this study, we investigated the performance of three three-dimensional multiecho sequences (MPRAGE, MP2RAGE, and FLASH) with scan times < 9 min and 1-mm isotropic resolution against their single-echo, low-bandwidth counterparts at 3T. We also compared the performance of multiparameter mapping (PD, T1 , and T2*) with bipolar multiecho MP2RAGE versus the variable flip angle technique with multiecho FLASH (VFA-FLASH).MethodsMultiecho sequences were optimized to yield equivalent contrast and improved SNR compared with their single-echo counterparts. Theoretical SNR gains were verified with measurements in a multilayered phantom. Robust image processing pipelines extracted PD, T1 , and T2* maps from MP2RAGE or VFA-FLASH, and the corresponding SNR was measured with varying SENSE accelerations (R = 1-5) and number of echoes (N = 1-12). All sequences were tested on four healthy volunteers.ResultsMultiecho sequences achieved SNR gains of 1.3-1.6 over single-echo sequences. MP2RAGE yielded comparable T1 -to-noise ratio to VFA-FLASH, but significantly lower SNR (<50%) in PD and T2* maps. Measured SNR gains agreed with the theoretical predictions for SENSE accelerations ≤3.ConclusionMultiecho sequences achieve higher SNR efficiency over conventional single-echo sequences, despite three-fold higher sampling bandwidths. VFA-FLASH surpasses MP2RAGE in its ability to map three parameters with high SNR and 1-mm isotropic resolution in a clinically relevant scan time (∼8:30 min), whereas MP2RAGE yields lower intersubject variability in T1 . Magn Reson Med 77:2186-2202, 2017. © 2016 International Society for Magnetic Resonance in Medicine.© 2016 International Society for Magnetic Resonance in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.