    AbstractDiffusion-weighted images based on echo planar sequences suffer from distortions due to field inhomogeneities from susceptibility differences as well as from eddy currents arising from diffusion gradients. In this paper, a novel approach using nonlinear warping based on optic flow to correct distortions of baseline and diffusion weighted echo planar images (EPI) acquired at 3 T is presented. The distortion correction was estimated by warping the echo planar images to the anatomically correct T2-weighted fast spin echo images (T2-FSE). A global histogram intensity matching of the T2-FSE precedes the base line EPI image distortion correction. A local intensity-matching algorithm was used to transform labeled T2-FSE regions to match intensities of diffusion-weighted EPI images prior to distortion correction of these images. Evaluation was performed using three methods: (i) visual comparison of overlaid contours, (ii) a global mutual information index, and (iii) a local distance measure between homologous points. Visual assessment and the global index demonstrated a decrease in geometrical distortion and the distance measure showed that distortions are reduced to a subvoxel level. In conclusion, the warping algorithm is effective in reducing geometric distortions, enabling generation of anatomically correct diffusion tensor images at 3 T.(c) 2005 Wiley-Liss, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…