• J Magn Reson Imaging · Sep 2015

    3 Tesla high-resolution and delayed gadolinium enhanced MR imaging of cartilage (dGEMRIC) after autologous chondrocyte transplantation in the hip.

    • Andrea Lazik, Konrad Körsmeier, Tim Claßen, Marcus Jäger, Michael Kamminga, Oliver Kraff, Thomas C Lauenstein, Jens M Theysohn, and Stefan Landgraeber.
    • Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
    • J Magn Reson Imaging. 2015 Sep 1; 42 (3): 624-33.

    BackgroundTo evaluate the feasibility of 3 Tesla (T) high-resolution and gadolinium enhanced MRI of cartilage (dGEMRIC) in the thin and rounded hip cartilage of patients after acetabular matrix-based autologous chondrocyte transplantation (MACT).MethodsUnder general ethics approval, 24 patients were prospectively examined 6-31 months after acetabular MACT at 3T using high-resolution proton-density weighted (PDw) images (bilateral PD SPACE, 0.8 mm isotropic; unilateral PD-TSE coronal/sagittal, 0.8 × 0.8 resp. 0.5 × 0.5 × 2.5 mm) as well as T1 mapping (3D-FLASH, 0.78 mm isotropic) in dGEMRIC technique, and clinically scored. The cartilage transplant was evaluated using an adapted MOCART score (maximum 85 points). T1 relaxation times were measured independently by two radiologists. Here, regions of interest were placed manually in automatically calculated relaxation-maps, both in the transplant and adjacent healthy cartilage regions. Interobserver reliability was estimated by means of intraclass-correlation (ICC).ResultsThe transplant was morphologically definable in the PDw images of 23 patients with a mean MOCART score of 69 points (60-80 points, SD 6.5). T1 maps showed a clear differentiation between acetabular and femoral cartilage, but correlation with PDw images was necessary to identify the transplant. Mean T1 relaxation times of the transplant were 616.3 ms (observer 1) resp. 610.1 ms (observer 2), and of adjacent healthy acetabular cartilage 574.5 ms (observer 1) resp. 604.9 ms (observer 2). Interobserver reliability of the relaxation times in the transplant was excellent (ICC-coefficient 0.88) and in adjacent healthy regions good (0.77).ConclusionHigh-resolution PDw imaging with adapted MOCART scoring and dGEMRIC is feasible after MACT in the thin and rounded hip cartilage.© 2014 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…