-
J Magn Reson Imaging · Nov 2012
Signal polarity restoration in a 3D inversion recovery sequence used with delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC).
- Jerzy Szumowski, Michael G Durkan, Erik W Foss, Dawson S Brown, Erwin Schwarz, and Dennis C Crawford.
- Oregon Health and Science University, Department of Radiology, Portland, Oregon 97239, USA.
- J Magn Reson Imaging. 2012 Nov 1; 36 (5): 1248-55.
PurposeTo develop an image reconstruction algorithm that restores the signal polarity in a three-dimensional inversion-recovery (3D-IR) sequence used in delayed gadolinium-enhanced MRI of cartilage (dGEMRIC). This approach effectively doubles the dynamic range of data used for T1 curve fitting.Materials And MethodsWe applied this reconstruction algorithm to a 3D-IR TFE sequence used for T1 mapping, validated the technique in a phantom study, and performed T1-map calculations in postosteochondral allograft transplant (OAT) patients. In addition, we performed a signal simulation study to assess the algorithm's capability to reduce the number of inversion times used in the 3D-IR TFE sequence.ResultsIn comparison to a standard T1-mapping algorithm that uses the magnitude of the MRI signal, the proposed algorithm improves the reliability of T1 relaxation fits to the inversion-recovery three-parameter function. The signal simulation study shows that the number of TI inversion times can be reduced to as few as four, without compromising the accuracy of T1 calculations.ConclusionThis algorithm can be applied to any 2D- or 3D-IR acquisition sequence used in conjunction with dGEMRIC. Application of the algorithm improves the reliability of T1 calculations and allows the number of TIs to be reduced, leading to shorter scan times in dGEMRIC.Copyright © 2012 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.