J Magn Reson Imaging · Oct 2007
Simultaneous myocardial and fat suppression in magnetic resonance myocardial delayed enhancement imaging.
- FooThomas K FTKMagnetic Resonance Imaging Laboratory, GE Global Research, Niskayuna, New York, USA. thomas.foo@research.ge.com, Glenn S Slavin, David A Bluemke, Marcela Montequin, Maureen N Hood, and Vincent B Ho.
- Magnetic Resonance Imaging Laboratory, GE Global Research, Niskayuna, New York, USA. thomas.foo@research.ge.com
- J Magn Reson Imaging. 2007 Oct 1; 26 (4): 927-33.
PurposeTo develop a method for fat suppression in myocardial delayed enhancement (MDE) studies that achieves effective signal intensity reduction in fat but does not perturb myocardial signal suppression.Materials And MethodsA new approach to fat suppression that uses a spectrally-selective inversion-recovery (SPEC-IR) tip-up radio frequency (RF) pulse following the conventional nonselective IR RF pulse together with a second SPEC-IR RF pulse is proposed. The tip-up pulse restores the fat longitudinal magnetization after the nonselective IR pulse and allows the fat magnetization to recover more fully toward its equilibrium value, providing for better fat suppression by the second SPEC-IR RF pulse. This new approach was validated in phantom studies and in five patients.ResultsEffective fat suppression was achieved using the proposed technique with minimal impact on normal myocardial signal suppression. Mean fat suppression achieved using this approach was 67% +/- 8%, as measured in the chest wall immediately opposite the heart.ConclusionThe results indicate this modular-type approach optimizes fat suppression in myocardial delayed enhancement studies but does not perturb the basic IR pulse sequence or change basic acquisition parameters.(c) 2007 Wiley-Liss, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.