• J Occup Environ Hyg · Jan 2016

    Respiratory protection for firefighters--Evaluation of CBRN canisters for use during overhaul II: In mask analyte sampling with integrated dynamic breathing machine.

    • Leaton Jones, Jefferey L Burgess, Heath Evans, and Eric A Lutz.
    • a Division of Community, Environment, and Policy, Mel and Enid Zuckerman College of Public Health, University of Arizona , Tucson , Arizona.
    • J Occup Environ Hyg. 2016 Jan 1; 13 (3): 177-84.

    AbstractAccording to the National Fire Protection Association there were 487,500 structural fires in the U.S. in 2013. After visible flames are extinguished firefighters begin the overhaul stage where remaining hot spots are identified and further extinguished. During overhaul, a significant amount of potentially hazardous chemicals can remain in the ambient environment. Previous research suggests that the use of air purifying respirators fitted with chemical, biological, radiological, and nuclear (CBRN) canisters may reduce occupational exposure. This study used large scale burns of representative structural materials to perform side-by-side, filtering, and service-life evaluations of commercially available CBRN filters using two head forms fitted with full-face respirators and a dynamic breathing machine. Three types of CBRN canisters and one non-CBRN cartridge were challenged in repetitive post-fire environments. Tests were conducted with two different breathing volumes and rates for two sampling durations (0-15 min and 0-60 min). Fifty-five different chemicals were selected for evaluation and results indicate that 10 of the 55 chemicals were present in the post-fire overhaul ambient environment. Acetaldehyde and formaldehyde were found to be the only two chemicals detected post filter but were effectively filtered to below ACGIH TLVs. Counter to our prior published work using continuous flow filter evaluation, this study indicates that, regardless of brand, CBRN filters were effective at reducing concentrations of post-fire ambient chemicals to below occupational exposure limits. However, caution should be applied when using CBRN filters as the ambient formaldehyde level in the current study was 8.9 times lower than during the previous work.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.