• J. Am. Coll. Cardiol. · Jan 1996

    Comparative Study

    Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography.

    • K A Williams and L A Taillon.
    • Department of Medicine (Cardiology), University of Chicago, Illinois 60637, USA.
    • J. Am. Coll. Cardiol. 1996 Jan 1; 27 (1): 173-81.

    ObjectivesThis study evaluated the use of gated single-photon emission computed tomographic (SPECT) myocardial perfusion images for determination of left ventricular ejection fraction.BackgroundGated SPECT has expanded the applications of myocardial perfusion imaging to include the evaluation of left ventricular size, regional wall motion and regional systolic thickening. Accurate automated or semi-automated methods for quantitation of left ventricular ejection fraction from tomographic perfusion images would provide additional valuable clinical information.MethodsRest gated SPECT was performed on the stress distribution of technetium-99m sestamibi, using eight frames per cardiac cycle. Mid-horizontal long-axis and vertical long-axis gated tomographic perfusion images were analyzed after digital matrix inversion, which enhances edge detection, for ejection fraction determination. These ejection fractions were compared with those determined by contrast ventriculography (n = 54, including 45 biplane and 9 single plane) and first-pass radionuclide angiography (n = 38) in patients with coronary artery disease.ResultsMyocardial perfusion SPECT image inversion-derived ejection fractions were slightly lower (2.7 ejection fraction units, p < 0.01), and first-pass ejection fractions were much lower (8.0 ejection fraction units, p < 0.001) than those obtained with contrast ventriculography. There was excellent correlation between SPECT and contrast ventriculographic ejection fractions (r = 0.93) over a wide range of ejection fractions (14% to 89%). Good correlation was also observed between first-pass radionuclide angiography and both contrast ventriculography (r = 0.83) and SPECT (r = 0.87). Reproducibility of SPECT image inversion ejection fractions was excellent (intraobserver r = 0.99, interobserver r = 0.93).ConclusionsSemiautomated ejection fractions can be obtained from gated SPECT technetium-99m sestamibi perfusion images using the image inversion technique. These results are reproducible and correlate well with results of first-pass radionuclide angiography but are closer in value to those obtained with contrast ventriculography.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…