• J Electrocardiol · Sep 2014

    Review

    Regression of electrocardiographic left ventricular hypertrophy or strain is associated with lower incidence of cardiovascular morbidity and mortality in hypertensive patients independent of blood pressure reduction - A LIFE review.

    • Casper N Bang, Richard B Devereux, and Peter M Okin.
    • Department of Medicine, Weill Cornell Medical College, NY, USA; Department of Cardiology, The Heart Center, Rigshospitalet, Copenhagen, Denmark. Electronic address: casperbang@hotmail.com.
    • J Electrocardiol. 2014 Sep 1; 47 (5): 630-5.

    AbstractCornell product criteria, Sokolow-Lyon voltage criteria and electrocardiographic (ECG) strain (secondary ST-T abnormalities) are markers for left ventricular hypertrophy (LVH) and adverse prognosis in population studies. However, the relationship of regression of ECG LVH and strain during antihypertensive therapy to cardiovascular (CV) risk was unclear before the Losartan Intervention for Endpoint Reduction in Hypertension (LIFE) study. We reviewed findings on ECG LVH regression and strain over time in 9193 hypertensive patients with ECG LVH at baseline enrolled in the LIFE study. The composite endpoint of CV death, nonfatal MI, or stroke occurred in 1096 patients during 4.8±0.9years follow-up. In Cox multivariable models adjusting for randomized treatment, known risk factors including in-treatment blood pressure, and for severity ECG LVH by Cornell product and Sokolow-Lyon voltage, baseline ECG strain was associated with a 33% higher risk of the LIFE composite endpoint (HR. 1.33, 95% CI [1.11-1.59]). Development of new ECG strain between baseline and year-1 was associated with a 2-fold increased risk of the composite endpoint (HR. 2.05, 95% CI [1.51-2.78]), whereas the risk associated with regression or persistence of ECG strain was attenuated and no longer statistically significant (both p>0.05). After controlling for treatment with losartan or atenolol, for baseline Framingham risk score, Cornell product, and Sokolow-Lyon voltage, and for baseline and in-treatment systolic and diastolic blood pressure, 1 standard deviation (SD) lower in-treatment Cornell product was associated with a 14.5% decrease in the composite endpoint (HR. 0.86, 95% CI [0.82-0.90]). In a parallel analysis, 1 SD lower in-treatment Sokolow-Lyon voltage was associated with a 16.6% decrease in the composite endpoint (HR. 0.83, 95% CI [0.78-0.88]). The LIFE study shows that evaluation of both baseline and in-study ECG LVH defined by Cornell product criteria, Sokolow-Lyon voltage criteria or ECG strain improves prediction of CV events and that regression of ECG LVH during antihypertensive treatment is associated with better outcome, independent of blood pressure reduction. Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…