    Comparison of Linear and Sector Array Probe for Handheld Lung Ultrasound in Invasively Ventilated ICU Patients.

    • Marry R Smit, Juliette de Vos, Luigi Pisani, Laura A Hagens, Chiara Almondo, Nanon F L Heijnen, Ronny M Schnabel, van der HorstIwan C CICCDepartment of Intensive Care, Maastricht UMC+, Maastricht, the Netherlands., BergmansDennis C J JDCJJDepartment of Intensive Care, Maastricht UMC+, Maastricht, the Netherlands., Marcus J Schultz, BosLieuwe D JLDJDepartment of Intensive Care, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, the Netherlands., and DARTS Consortium.
    • Department of Intensive Care, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, the Netherlands. Electronic address: m.r.smit@amsterdamumc.nl.
    • Ultrasound Med Biol. 2020 Dec 1; 46 (12): 3249-3256.

    AbstractInternational guidelines do not recommend a specific probe for assessment of lung aeration using lung ultrasound (LUS). The aim of this study was to assess the concordance between linear and sector array probes of a handheld ultrasound device in assessment of lung aeration in invasively ventilated intensive care unit patients. This study included intensive care unit patients who were expected to be ventilated for longer than 24 h. A 12-region LUS exam was performed with a linear and a sector array probe. In each image, the LUS aeration score and number of B-lines were determined. Adding the LUS aeration scores of all regions resulted in a global LUS aeration score. Agreement between the two probes was calculated using intra-class correlation coefficients (ICCs). A total of 30 LUS exams were performed in 19 patients, resulting in a total of 328 pairs of images. Twenty-nine pairs of images were excluded from analysis because the images from the linear probe could not be scored. ICCs calculated for the remaining images revealed good concordance the LUS aeration scores for individual images (ICC = 0.73, 95% confidence interval 0.67-0.78), number of B-lines (ICC = 0.79, 95% confidence interval 0.72-0.83) and global LUS aeration score (ICC = 0.74, 95% confidence interval 0.52-0.87). In conclusion, there is good concordance between linear and sector array probes of a handheld ultrasound device in assessment of lung aeration patterns in mechanically ventilated intensive care unit patients. However, in roughly 10% of the images acquired using the linear probe, the aeration pattern could not be scored.Copyright © 2020 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.