IEEE Trans Med Imaging · Sep 2003
Comparative StudyLimits on the accuracy of 3-D thickness measurement in magnetic resonance images--effects of voxel anisotropy.
- Yoshinobu Sato, Hisashi Tanaka, Takashi Nishii, Katsuyuki Nakanishi, Nobuhiko Sugano, Tetsuya Kubota, Hironobu Nakamura, Hideki Yoshikawa, Takahiro Ochi, and Shinichi Tamura.
- Division of Interdisciplinary Image Analysis, Osaka University Graduate School of Medicine, Suita, Japan. yoshi@image.med.osaka-u.ac.jp
- IEEE Trans Med Imaging. 2003 Sep 1; 22 (9): 1076-88.
AbstractMeasuring the thickness of sheet-like thin anatomical structures, such as articular cartilage and brain cortex, in three-dimensional (3-D) magnetic resonance (MR) images is an important diagnostic procedure. This paper investigates the fundamental limits on the accuracy of thickness determination in MR images. We defined thickness here as the distance between the two sides of boundaries measured at the subvoxel resolution, which are the zero-crossings of the second directional derivatives combined with Gaussian blurring along the normal directions of the sheet surface. Based on MR imaging and computer postprocessing parameters, characteristics for the accuracy of thickness determination were derived by a theoretical simulation. We especially focused on the effects of voxel anisotropy in MR imaging with variable orientation of sheet-like structure. Improved and stable accuracy features were observed when the standard deviation of Gaussian blurring combined with thickness determination processes was around square root of 2/2 times as large as the pixel size. The relation between voxel anisotropy in MR imaging and the range of sheet normal orientation within which acceptable accuracy is attainable was also clarified, based on the dependences of voxel anisotropy and the sheet normal orientation obtained by numerical simulations. Finally, in vitro experiments were conducted using an acrylic plate phantom and a resected femoral head to validate the results of theoretical simulation. The simulated thickness was demonstrated to be well-correlated with the actual in vitro thickness.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.