Microvascular research · Jul 1994
Spatial heterogeneity in normal skin perfusion recorded with laser Doppler imaging and flowmetry.
- K Wårdell, I M Braverman, D G Silverman, and G E Nilsson.
- Department of Biomedical Engineering, Linköping University, Sweden.
- Microvasc. Res. 1994 Jul 1; 48 (1): 26-38.
AbstractSpatial and temporal variations in forearm skin perfusion captured by laser Doppler perfusion imaging (LDI) have been compared with topographic maps recorded by laser Doppler flowmetry. In order to determine the shortest LDI sampling time required at each measurement site, with an adequate signal-to-noise ratio and with the ability to display the heterogeneity in skin perfusion, the noise-limited resolution of the LDI system as well as various sampling times were tested. The noise-limited resolution for medium and high light intensities were less than 0.5% (temporal) and 0.3% (spatial) of full scale. A sampling time of 1 sec was selected and image presentation was made by performing bilinear interpolation between perfusion values. The same area (10 x 10 mm) was mapped with LDI and topographic mapping at seven different sites. In addition, a larger area covering the surrounding skin was recorded with LDI. The small area recordings with LDI and topographic mapping could be identified in the larger LDI image. High-and low-perfusion spots coincided between the two systems. Temporal variations were studied by repeated LDI recordings of the same areas as above. Small spots were selected in the areas and plotted versus time. Without provocation, the total perfusion changes at each spot showed large variations, but the relative perfusion levels between neighboring spots persisted. Provocation with heat increased the perfusion in all spots.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.