Clin Physiol Funct Imaging · Mar 2018
Oesophageal Doppler guided optimization of cardiac output does not increase visceral microvascular blood flow in healthy volunteers.
- Thomas P Heinink, David J Read, William K Mitchell, Ashish Bhalla, Jonathan N Lund, Bethan E Phillips, and John P Williams.
- Department of Anaesthesia and Critical Care, Royal Derby Hospital, Derby, UK.
- Clin Physiol Funct Imaging. 2018 Mar 1; 38 (2): 213-219.
BackgroundOesophageal Doppler monitoring (ODM) is used clinically to optimize cardiac output (CO) and guide fluid therapy. Despite limited experimental evidence, it is assumed that increasing CO increases visceral microvascular blood flow (MBF). We used contrast-enhanced ultrasound (CEUS) to assess whether ODM-guided optimization of CO altered MBF.MethodsSixteen healthy male volunteers (62 ± 3·4 years) were studied. Baseline measurements of CO were recorded via ODM. Hepatic and renal MBF was assessed via CEUS. Saline 0·9% was administered to optimize CO according to a standard protocol and repeat CEUS performed. Time-intensity curves were constructed, allowing organ perfusion calculation via time to 5% perfusion (TT5). MBF was assessed via organ perfusion rise time (RT) (5-95%).ResultsCO increased (4535 ± 241 ml/min versus 5442 ± 329 ml/min, P<0·0001) following fluid administration, whilst time to renal (22·48 ± 1·19 s versus 20·79 ± 1·31 s; P = 0·03), but not hepatic (28·13 ± 4·48 s versus 26·83 ± 1·53 s; P = 0·15) perfusion decreased. Time to renal perfusion was related to CO (renal: r = -0·43, P = 0·01). Hepatic nor renal RT altered following fluid administration (renal: 9·03 ± 0·86 versus 8·93 ± 0·85 s P = 0·86; hepatic: 27·86 ± 1·60 s versus 30·71 ± 2·19 s, P = 0·13). No relationship was observed between changes in CO and MBF in either organ (renal: r = -0·17, P = 0·54; hepatic: r = -0·07, P = 0·80).ConclusionsODM-optimized CO reduces time to renal perfusion but does not alter renal or hepatic MBF. A lack of relationship between microvascular visceral perfusion and CO following ODM-guided optimization may explain the absence of improved clinical outcome with ODM monitoring.© 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.