• Ann. Rheum. Dis. · Dec 2008

    Multicenter Study Clinical Trial

    Precision of 3.0 Tesla quantitative magnetic resonance imaging of cartilage morphology in a multicentre clinical trial.

    • F Eckstein, R J Buck, D Burstein, H C Charles, J Crim, M Hudelmaier, D J Hunter, G Hutchins, C Jackson, V Byers Kraus, N E Lane, T M Link, L S Majumdar, S Mazzuca, P V Prasad, T J Schnitzer, M S Taljanovic, A Vaz, B Wyman, M-P Hellio Le Graverand, and A9001140 Study Group.
    • Institute of Anatomy and Musculoskeletal Research, PMU, Strubergasse 21, A5020 Salzburg Austria. felix.eckstein@pmu.ac.at
    • Ann. Rheum. Dis. 2008 Dec 1; 67 (12): 1683-8.

    ObjectiveQuantitative MRI (qMRI) of cartilage morphology is a promising tool for disease-modifying osteoarthritis drug (DMOAD) development. Recent studies at single sites have indicated that measurements at 3.0 Tesla (T) are more reproducible (precise) than those at 1.5 T. Precision errors and stability in multicentre studies with imaging equipment from various vendors have, however, not yet been evaluated.MethodsA total of 158 female participants (97 Kellgren and Lawrence grade (KLG) 0, 31 KLG 2 and 30 KLG 3) were imaged at 7 clinical centres using Siemens Magnetom Trio and GE Signa Excite magnets. Double oblique coronal acquisitions were obtained at baseline and at 3 months, using water excitation spoiled gradient echo sequences (1.0x0.31x0.31 mm3 resolution). Segmentation of femorotibial cartilage morphology was performed using proprietary software (Chondrometrics GmbH, Ainring, Germany).ResultsThe precision error (root mean square coefficient of variation (RMS CV)%) for cartilage thickness/volume measurements ranged from 2.1%/2.4% (medial tibia) to 2.9%/3.3% (lateral weight-bearing femoral condyle) across all participants. No significant differences in precision errors were observed between KLGs, imaging sites, or scanner manufacturers/types. Mean differences between baseline and 3 months ranged from <0.1% (non-significant) in the medial to 0.94% (p<0.01) in the lateral femorotibial compartment, and were 0.33% (p<0.02) for the total femorotibial subchondral bone area.ConclusionsqMRI performed at 3.0 T provides highly reproducible measurements of cartilage morphology in multicentre clinical trials with equipment from different vendors. The technology thus appears sufficiently robust to be recommended for large-scale multicentre trials.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…