• J. Nucl. Med. · Jul 2009

    Multicenter Study

    Qualification of PET scanners for use in multicenter cancer clinical trials: the American College of Radiology Imaging Network experience.

    • Joshua S Scheuermann, Janet R Saffer, Joel S Karp, Anthony M Levering, and Barry A Siegel.
    • Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. jscheu@mail.med.upenn.edu
    • J. Nucl. Med. 2009 Jul 1; 50 (7): 1187-93.

    UnlabelledThe PET Core Laboratory of the American College of Radiology Imaging Network (ACRIN) qualifies sites to participate in multicenter research trials by quantitatively reviewing submitted PET scans of uniform cylinders to verify the accuracy of scanner standardized uptake value (SUV) calibration and qualitatively reviewing clinical PET images from each site. To date, cylinder and patient data from 169 PET scanners have been reviewed, and 146 have been qualified.MethodsEach site is required to submit data from 1 uniform cylinder and 2 patient test cases. Submitted phantom data are analyzed by drawing a circular region of interest that encompasses approximately 90% of the diameter of the interior of the phantom and then recording the mean SUV and SD of each transverse slice. In addition, average SUVs are measured in the liver of submitted patient scans. These data illustrate variations of SUVs across PET scanners and across institutions, and comparison of results with values submitted by the site indicate the level of experience of PET camera operators in calculating SUVs.ResultsOf 101 scanner applications for which detailed records of the qualification process were available, 12 (12%) failed because of incorrect SUV or normalization calibrations. For sites to pass, the average cylinder SUV is required to be 1.0 +/- 0.1. The average SUVs for uniform cylinder images for the most common scanners evaluated-Siemens Biograph PET/CT (n = 43), GE Discovery LS PET/CT (n = 15), GE Discovery ST PET/CT (n = 34), Philips Allegro PET (n = 5), and Philips Gemini PET/CT (n = 11)-were 0.99, 1.01, 1.00, 0.98, and 0.95, respectively, and the average liver SUVs for submitted test cases were 2.34, 2.13, 2.27, 1.73, and 1.92, respectively.ConclusionMinimizing errors in SUV measurement is critical to achieving accurate quantification in clinical trials. The experience of the ACRIN PET Core Laboratory shows that many sites are unable to maintain accurate SUV calibrations without additional training or supervision. This raises concerns about using SUVs to quantify patient data without verification.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.