• J Magn Reson Imaging · Jun 2007

    Contrast-to-noise ratio (CNR) as a quality parameter in fMRI.

    • Alexander Geissler, Andreas Gartus, Thomas Foki, Amir Reza Tahamtan, Roland Beisteiner, and Markus Barth.
    • Clinical fMRI Study Group, Departments of Neurology, Neurosurgery, and Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
    • J Magn Reson Imaging. 2007 Jun 1; 25 (6): 1263-70.

    PurposeTo evaluate the impact of data quality on the localization of brain activation in functional magnetic resonance imaging (fMRI) and to explore whether the temporal contrast-to-noise-ratio (CNR) provides a quantitative parameter to estimate fMRI quality.Materials And MethodsWe investigated two methods for defining the CNR by comparing them on a single-run, single session, as well as on a group-wise basis. The CNRs of healthy subjects and a group of patients with brain lesions were calculated using two different strategies: one based on a general linear model (GLM) analysis (CNR_SPM), and one that acts as an adaptive low-pass filter and assumes that the high-frequency components contain the temporal noise (CNR_SG). Runs with low CNR were identified as outliers using a common exclusion criterion (2 x standard deviation (SD)).ResultsThe results of the two CNR methods are highly correlated. Both between and within subjects and patients the CNR showed quite large variations, but the average CNR did not differ between a group of healthy subjects and a patient group. In total, seven of 213 runs (3.3% of all runs) had to be excluded when CNR_SG was used, and 14 of 213 (6.6%) runs had to be excluded when CNR_SPM was used.ConclusionCalculating the CNR using an adaptive low-pass filter gives similar results to a GLM-based approach and could be advantageous for cases in which the hemodynamic response function (HRF) differs significantly from common assumptions. The CNR can be used to identify and exclude runs with suboptimal CNR, and to identify sessions with insufficient data quality. The CNR may serve as a quantitative and intuitive parameter to assess the performance and quality of clinical fMRI investigations, including information on both functional performance (contrast) and data quality (noise caused by the system and physiology).(c) 2007 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…