• Catheter Cardiovasc Interv · Dec 2011

    Transcatheter valve in valve implantation for failed mitral and tricuspid bioprosthesis.

    • Alfredo Giuseppe Cerillo, Francesca Chiaramonti, Michele Murzi, Stefano Bevilacqua, Elisa Cerone, Cataldo Palmieri, Paolo Del Sarto, Massimiliano Mariani, Sergio Berti, and Mattia Glauber.
    • Operative Unit of Cardiac Surgery, G. Pasquinucci Hospital, G. Monasterio Foundation, Massa, Italy. acerillo@yahoo.com
    • Catheter Cardiovasc Interv. 2011 Dec 1; 78 (7): 987-95.

    ObjectiveWe report our experience with the transapical transcatheter "Valve in valve" implantation (T-VIV) in patients with a failed mitral or tricuspid bioprosthesis; we briefly review the pertinent literature, and discuss some technical aspects of this procedure.BackgroundRedo valve surgery for failure of a mitral or tricuspid bioprosthesis might become extremely challenging, both because of the patients' condition, which is frequently poor, and for the technical aspects of the operation itself, that can be very demanding. T-VIV has been widely employed with good results for the treatment of aortic bioprosthesis failure, and could represent an attractive option in this setting.MethodsFour patients with multiple comorbidities (age: 63-83 years; logistic Euroscore: 37.2-81.5) underwent T-VIV at our institution for failure of a mitral [3] or tricuspid [1] bioprosthesis. A 26 mm Sapien valve was used in all cases. All the mitral procedures were performed via a transapical approach. The tricuspid procedure was performed via a transjugular approach.ResultsThe first mitral procedure was complicated by the splaying of the xenograft stents and embolization of the valve. The procedure was converted to conventional surgery, and the patient died on postoperative day 1. In the subsequent procedures, the valve was positioned more atrially, and was fixed to the malfunctioning xenograft sewing ring. All subsequent procedures were successful, all patients were discharged home and were alive and well at follow-up.ConclusionsThe results of T-VIV procedure in the mitral position have been suboptimal, and four of the sixteen patients reported to date died. However, all patients were extremely diseased, and some of the reported failures were related to amendable technical factors relative to the surgical access or to the valve deployment technique. With increasing experience, this procedure might become indicated as an alternative to conventional surgery in selected patients, encouraging increased use of bioprosthesis, and marking a pivotal change in the management of valvular disease.Copyright © 2011 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…