• J. Vasc. Surg. · May 2017

    Semiautomatic quantification of carotid plaque volume with three-dimensional ultrasound imaging.

    • Amir A Khan, Christian Koudelka, Carly Goldstein, Limin Zhao, John Yokemick, Moira Dux, Siddhartha Sikdar, and Brajesh K Lal.
    • Department of Bioengineering, George Mason University, Fairfax, Va; Division of Vascular Surgery, Center for Vascular Diagnostics, University of Maryland School of Medicine, Baltimore, Md.
    • J. Vasc. Surg. 2017 May 1; 65 (5): 1407-1417.

    ObjectiveVessel wall volume (VWV) assessed by three-dimensional duplex ultrasound (3DUS) imaging provides a more comprehensive measure of plaque burden than conventional two-dimensional measures of diameter stenosis. We previously demonstrated that manual outlining of the arterial lumen-intima boundary and outer wall boundary can be performed reliably on images obtained with a commercially available 3D-DUS transducer. Manual segmentation, however, is time consuming (∼45 minutes), limiting its clinical translation. We have developed a semiautomatic algorithm (manual selection of the carotid bifurcation image with subsequent automatic plaque outlining) to outline carotid plaques on 3DUS data sets. In this study, we investigated the accuracy, reproducibility, reliability, and time taken by this algorithm.Methods3DUS data sets from 30 patients with asymptomatic ≥50% carotid stenosis underwent manual outlining of lumen-intima boundary and outer wall boundary to measure VWV. Two observers implemented a semiautomatic segmentation algorithm. The algorithm's accuracy was compared with manual outlining using the Pearson correlation coefficient. The Dice similarity coefficient (DSC) and modified-Hausdorff distance (MHD) were used to quantify the geometric similarity of the outlines. We also compared results after an intermediate stage of the algorithm vs the complete algorithm. Reproducibility and the least amount of detectable change in plaque volume were computed for each method. Intraobserver and interobserver metrics for each method were computed using the intraclass correlation coefficient (ICC), coefficient of variability (CV), minimum detectable change (MDC), and standard error of measurement (SEM) of the VWV.ResultsPlaque volume estimates obtained from the semiautomatic algorithm were accurate compared with manual outlining. The Pearson correlation coefficient was 0.76 (P < .001), and measurements were geometrically similar (DSC, 0.85; MHD, 0.48 mm). The algorithm was more reproducible and reliable and could detect smaller changes in plaque volume on repeat imaging (low interobserver variability: ICC, 0.9; CV, 8.22%; MDC, 5.57%; SEM, 1.45%; DSC, 0.88; MHD, 0.43 mm). Intraobserver variability was even lower (ICC, 0.9; CV, 8%; MDC, 3.62%; SEM, 1.31%; DSC, 0.89; MHD, 0.37 mm). Plaque volume estimates at the intermediate stage of the algorithm matched results from the full algorithm (Pearson correlation coefficient, 0.76; DSC, 0.84; MHD, 0.52 mm). The intermediate approach, however, was less reliable than the full algorithm (interobserver: ICC, 0.81; CV, 11.7%; MDC, 9.58%; SEM, 3.46%; DSC, 0.88; MHD, 0.42 mm; intraobserver: ICC, 0.87; CV, 8.6%; MDC, 4.55%; SEM, 1.64%; DSC, 0.89; MHD, 0.38 mm). The full algorithm required ∼14 minutes to implement. However, a quick (7 minutes) and accurate assessment of VWV can be obtained by running only the intermediate stage of the algorithm, although with a loss in repeatability and reliability.ConclusionsWe present a unique algorithm to perform semiautomatic quantification of carotid plaque volume using 3DUS imaging. It is quick (mean time, 14 minutes), accurate, repeatable, and implementable in a clinical environment and in longitudinal studies tracking plaque progression. It reliably detects plaque volume changes as low as 4% to 6% with 95% confidence.Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.