• Am. J. Surg. · Oct 2006

    Multicenter Study

    Preliminary results and evaluation of MammoSite balloon brachytherapy for partial breast irradiation for pure ductal carcinoma in situ: a phase II clinical study.

    • Pamela R Benitez, Oscar Streeter, Frank Vicini, Vivek Mehta, Coral Quiet, Robert Kuske, Mary Katherine Hayes, Doug Arthur, Henry Kuerer, Gary Freedman, Martin Keisch, Thomas Dipetrillo, David Khan, and Richard Hudes.
    • Department of Surgery, William Beaumont Hospital, 3577 W. 13 Mile Rd., Suite #201, Royal Oak, MI 48073, USA. pbenitez@beaumont.edu
    • Am. J. Surg. 2006 Oct 1; 192 (4): 427-33.

    BackgroundThis report presents the preliminary results and evaluation of the MammoSite balloon catheter (MammoSite Radiation Therapy System; Cytyc Corporation, Marlboro, MA) as the sole method of delivering partial breast irradiation to the lumpectomy bed with breast-conserving surgery in patients with pure ductal carcinoma in situ (DCIS).MethodsTwelve institutions are participating in this phase II clinical study. A total of 133 patients have been enrolled and 100 patients have successfully completed the prescribed radiation therapy. A dose of 34 Gy was delivered in 10 fractions over 5 days prescribed to 1 cm from the applicator surface using iridium-192 high-dose rate brachytherapy. Patients who met the following criteria were selected for enrollment into the study: age 45 years or older, unicentric pure DCIS, mammographic lesion of 3 cm or less, negative margins as defined by 1 mm or more, postoperative final gross pathologic size of tumor of 5 cm or less, clinically node negative, and a postlumpectomy mammogram showing the absence of any residual suspicious microcalcifications. The placement of the MammoSite catheter was performed either at the time of the lumpectomy or postlumpectomy. The minimum distance from the balloon surface to the surface of the skin is greater than 5 mm. Data collection points are at time of enrollment, time of implant, 3 months, 6 months, and then yearly at 1- to 5-year follow-up visits. Data collected are local control rates, cosmetic outcome using the Harvard Scale, toxicities, serious adverse events, disease-free survival, cause-specific survival, and contralateral breast failure. The Van Nuys Prognostic Index scores were calculated for each patient. Local recurrence is defined as either invasive or noninvasive recurrence within the target volume. Ipsilateral elsewhere recurrence is defined as either an invasive or noninvasive recurrence occurring outside of the target volume in the previously treated breast. This recurrence is classified as a new primary tumor.ResultsThe mean follow-up period was 9.5 months (range, 1-24 mo). The MammoSite catheter was explanted for the following reasons: inadequate skin distance (5.1%; 6 of 117), poor cavity conformance (5.1%; 6 of 117), positive margins (2.6%; 3 of 117), final histology (.85%; 1 of 117), and physician decision (.85%; 1 of 117). Of the patients in whom the MammoSite was explanted because of skin spacing or cavity conformance, 50% were at sites of new users (institutions that have placed fewer than 10 Mammosite catheters). Cosmetic results were rated as excellent in 63%, good in 35%, and fair in 2% in the 86 patients with a follow-up visit. Two patients were diagnosed with an ipsilateral local recurrence, 1 outside of the target volume and 1 true recurrence/marginal miss. One patient was diagnosed at 8 months and the other was diagnosed at 11 months. Both of these ipsilateral failures were DCIS. The Van Nuys Prognostic Index of these 2 patients was 9 and 8, respectively. Data collected showed the mean age at placement was 60.8 y, mean tumor size was 10.6 mm, mean actual closest surgical margin was 6.8 mm (range, .1-40 mm), a re-excision rate of 35%, postlumpectomy placement was 71%, and the mean skin-to-balloon surface distance was 13 mm with 89% > or =7 mm. No serious adverse events were reported. The infection rate was 4.0%.ConclusionsAccelerated partial breast irradiation delivered with the MammoSite balloon was clinically successful in patients entered into a phase II clinical study with pure DCIS, with results comparable with other studies reported in the literature that have evaluated use of the MammoSite balloon brachytherapy for delivery of radiation therapy in early breast cancers. Inadequate skin distance and poor cavity conformance were the main factors limiting the use of the MammoSite device. Cosmetic results were good to excellent in 98%. There have been 2 ipsilateral breast recurrences.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.